Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-15 13:26 to 2018-09-15 17:18 UTC
Where: 34° 38.6' S 154° 34.3' E
Maximum Depth (m): 4498.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 6.3 | 250.59 | 35.625 | 1.66 | 16.82 | 0.24 | 0.06 | 0.14 | 0.82 |
33 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 16.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 15.8 | < 0.02 | < 0.02 | 1.65 | 16.82 | 0.24 | 0.06 | 0.14 | 0.81 |
26 | 31.1 | < 0.02 | < 0.02 | 13.66 | 16.82 | 0.99 | 0.02 | 0.05 | 15.35 |
25 | 40.1 | < 0.02 | < 0.02 | 1.67 | 16.79 | 0.24 | 0.06 | 0.14 | 0.78 |
24 | 50.3 | < 0.02 | < 0.02 | 2.29 | 16.23 | 0.29 | 0.30 | 0.22 | 0.69 |
23 | 59.8 | < 0.02 | < 0.02 | 2.09 | 16.12 | 0.28 | 0.39 | 0.20 | 0.74 |
22 | 69.4 | < 0.02 | < 0.02 | 17.78 | 16.11 | 1.25 | < 0.02 | 0.05 | 22.60 |
21 | 101 | 245.90 | 35.566 | 4.69 | 15.55 | 0.42 | < 0.02 | 0.16 | 1.30 |
20 | 124.7 | < 0.02 | < 0.02 | 4.65 | 15.19 | 0.43 | < 0.02 | 0.03 | 1.28 |
19 | 150.5 | < 0.02 | < 0.02 | 5.62 | 14.90 | 0.48 | < 0.02 | 0.03 | 1.49 |
18 | 201.6 | < 0.02 | < 0.02 | 10.43 | 13.55 | 0.77 | < 0.02 | < 0.02 | 3.00 |
17 | 299.8 | < 0.02 | < 0.02 | 14.10 | 11.62 | 1.00 | < 0.02 | < 0.02 | 4.40 |
16 | 502.1 | 223.22 | 34.628 | 21.26 | 8.74 | 1.46 | < 0.02 | < 0.02 | 8.85 |
15 | 750.1 | 198.12 | 34.447 | 32.85 | 6.09 | 2.27 | < 0.02 | < 0.02 | 51.50 |
14 | 1000.6 | 180.52 | 34.460 | 32.84 | 4.48 | 2.27 | < 0.02 | < 0.02 | 51.62 |
13 | 1099.5 | 174.45 | 34.486 | 33.83 | 4.06 | 2.36 | < 0.02 | < 0.02 | 61.87 |
12 | 1250.1 | 164.35 | 34.530 | 35.03 | 3.54 | 2.45 | < 0.02 | < 0.02 | 76.06 |
11 | 1499.9 | 161.99 | 34.598 | 35.79 | 2.83 | 2.52 | < 0.02 | < 0.02 | 91.61 |
10 | 1751.2 | 166.67 | 34.645 | 35.32 | 2.46 | 2.48 | < 0.02 | < 0.02 | 96.31 |
9 | 1998.7 | 182.31 | 34.680 | 34.44 | 2.25 | 2.40 | < 0.02 | < 0.02 | 94.83 |
8 | 2250.8 | 182.66 | 34.707 | 33.66 | 2.05 | 2.35 | < 0.02 | < 0.02 | 96.34 |
7 | 2499.7 | 188.69 | 34.722 | 33.25 | 1.86 | 2.32 | < 0.02 | < 0.02 | 100.34 |
6 | 2751.3 | 192.98 | 34.725 | 33.27 | 1.65 | 2.31 | < 0.02 | < 0.02 | 105.89 |
5 | 2999.4 | 196.20 | 34.724 | 33.37 | 1.47 | 2.32 | < 0.02 | < 0.02 | 110.62 |
4 | 3500.3 | 200.80 | 34.718 | 33.68 | 1.19 | 2.34 | < 0.02 | < 0.02 | 118.50 |
3 | 4000.9 | 201.47 | 34.715 | 33.82 | 1.16 | 2.36 | < 0.02 | < 0.02 | 120.47 |
2 | 4250.6 | 201.78 | 34.716 | 33.91 | 1.17 | 2.36 | < 0.02 | < 0.02 | 121.31 |
1 | 4498.6 | 201.91 | 34.715 | 33.93 | 1.19 | 2.34 | < 0.02 | < 0.02 | 121.03 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |