Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-15 09:19 to 2018-09-15 11:15 UTC
Where: 34° 38.9' S 154° 33.9' E
Maximum Depth (m): 1500.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 6 | < 0.02 | < 0.02 | 1.23 | 17.26 | 0.21 | 0.08 | 0.11 | 0.85 |
36 | 6.8 | 251.58 | 35.628 | < 0.02 | 17.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 14.8 | < 0.02 | < 0.02 | 1.24 | 17.26 | 0.22 | 0.07 | 0.11 | 0.87 |
34 | 15.1 | < 0.02 | < 0.02 | < 0.02 | 17.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 19.9 | < 0.02 | < 0.02 | < 0.02 | 17.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 20 | < 0.02 | < 0.02 | 1.22 | 17.26 | 0.21 | 0.08 | 0.11 | 0.91 |
29 | 30.5 | < 0.02 | < 0.02 | 1.72 | 16.48 | 0.24 | 0.16 | 0.14 | 0.72 |
30 | 30.9 | < 0.02 | < 0.02 | < 0.02 | 16.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 16.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 40.9 | < 0.02 | < 0.02 | 1.94 | 16.39 | 0.26 | 0.23 | 0.16 | 0.80 |
25 | 50.9 | < 0.02 | < 0.02 | 2.15 | 16.36 | 0.27 | 0.25 | 0.18 | 0.77 |
26 | 51 | < 0.02 | < 0.02 | < 0.02 | 16.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 58.7 | < 0.02 | < 0.02 | < 0.02 | 16.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 58.8 | < 0.02 | < 0.02 | 2.77 | 16.23 | 0.31 | 0.24 | 0.24 | 0.89 |
21 | 69.6 | < 0.02 | < 0.02 | 4.28 | 15.90 | 0.39 | 0.03 | 0.34 | 1.34 |
22 | 69.7 | < 0.02 | < 0.02 | < 0.02 | 15.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 99.5 | < 0.02 | < 0.02 | < 0.02 | 15.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 99.6 | 225.63 | 35.521 | 6.02 | 15.36 | 0.50 | < 0.02 | 0.05 | 1.81 |
18 | 123.9 | < 0.02 | < 0.02 | < 0.02 | 14.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 123.9 | < 0.02 | < 0.02 | 8.12 | 14.78 | 0.64 | < 0.02 | 0.04 | 2.41 |
16 | 150 | < 0.02 | < 0.02 | 7.37 | 14.74 | 0.59 | < 0.02 | 0.03 | 2.19 |
15 | 200.4 | < 0.02 | < 0.02 | 9.75 | 13.81 | 0.74 | < 0.02 | 0.02 | 2.97 |
14 | 299.5 | 210.62 | 35.008 | 14.50 | 11.52 | 1.04 | < 0.02 | < 0.02 | 4.75 |
13 | 399.8 | 214.82 | 34.779 | 18.05 | 9.92 | 1.26 | < 0.02 | < 0.02 | 6.35 |
12 | 500.3 | 215.31 | 34.637 | 20.84 | 8.83 | 1.44 | < 0.02 | < 0.02 | 8.59 |
11 | 599.9 | 206.33 | 34.553 | 23.49 | 7.97 | 1.62 | < 0.02 | < 0.02 | 12.80 |
10 | 701.9 | < 0.02 | < 0.02 | 28.00 | 6.18 | 1.94 | < 0.02 | < 0.02 | 25.38 |
9 | 800.3 | 193.92 | 34.442 | 29.52 | 5.64 | 2.05 | < 0.02 | < 0.02 | 32.42 |
8 | 900.6 | 187.49 | 34.446 | 31.12 | 5.11 | 2.16 | < 0.02 | < 0.02 | 40.93 |
7 | 1000.3 | < 0.02 | < 0.02 | 32.55 | 4.49 | 2.27 | < 0.02 | < 0.02 | 52.27 |
6 | 1101.3 | 172.84 | 34.491 | 33.69 | 3.99 | 2.36 | < 0.02 | < 0.02 | 63.31 |
5 | 1201.6 | < 0.02 | < 0.02 | 34.50 | 3.63 | 2.43 | < 0.02 | < 0.02 | 74.38 |
4 | 1300.1 | 160.73 | 34.549 | 35.01 | 3.36 | 2.48 | < 0.02 | < 0.02 | 81.65 |
3 | 1400.7 | < 0.02 | < 0.02 | 35.33 | 3.06 | 2.50 | < 0.02 | < 0.02 | 86.74 |
2 | 1499.9 | < 0.02 | < 0.02 | < 0.02 | 2.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1500.2 | 159.40 | 34.600 | 35.43 | 2.81 | 2.51 | < 0.02 | < 0.02 | 91.49 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |