Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-14 16:22 to 2018-09-14 21:04 UTC
Where: 35° 57.2' S 152° 52.0' E
Maximum Depth (m): 4924.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
31 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 6.5 | < 0.02 | < 0.02 | 1.28 | 19.33 | 0.19 | 0.03 | 0.37 | 0.76 |
27 | 15.4 | 229.33 | 35.745 | 1.28 | 19.33 | 0.19 | 0.03 | 0.37 | 0.77 |
26 | 31.8 | < 0.02 | < 0.02 | 1.28 | 19.33 | 0.33 | 0.61 | 0.37 | 0.77 |
25 | 39.4 | < 0.02 | < 0.02 | 1.30 | 19.33 | 0.19 | 0.04 | 0.38 | 0.77 |
24 | 50.5 | < 0.02 | < 0.02 | 1.32 | 19.33 | 0.19 | 0.02 | 0.39 | 0.79 |
23 | 59.3 | < 0.02 | < 0.02 | 1.32 | 19.33 | 0.18 | 0.03 | 0.38 | 0.75 |
22 | 70.8 | < 0.02 | < 0.02 | 1.37 | 19.33 | 0.18 | 0.02 | 0.40 | 0.76 |
21 | 100.4 | 228.62 | 35.746 | 1.37 | 19.33 | 0.18 | < 0.02 | 0.40 | 0.78 |
20 | 125 | < 0.02 | < 0.02 | 1.40 | 19.33 | 0.18 | 0.03 | 0.42 | 0.76 |
19 | 150.8 | < 0.02 | < 0.02 | 1.44 | 19.33 | 0.19 | 0.04 | 0.45 | 0.77 |
18 | 201 | < 0.02 | < 0.02 | 1.77 | 19.27 | 0.21 | < 0.02 | 0.37 | 0.84 |
17 | 300 | < 0.02 | < 0.02 | 5.20 | 17.26 | 0.44 | < 0.02 | 0.04 | 1.73 |
16 | 499.5 | 213.17 | 35.099 | 12.99 | 12.03 | 0.94 | 0.02 | < 0.02 | 4.70 |
15 | 750.7 | 214.51 | 34.768 | 18.68 | 9.58 | 1.30 | < 0.02 | < 0.02 | 7.91 |
14 | 1000.2 | 199.86 | 34.462 | 27.38 | 6.55 | 1.88 | < 0.02 | < 0.02 | 22.81 |
13 | 1099.1 | 193.78 | 34.447 | 29.38 | 5.79 | 2.03 | < 0.02 | < 0.02 | 31.71 |
12 | 1250 | 182.26 | 34.460 | 32.02 | 4.72 | 2.23 | < 0.02 | < 0.02 | 49.05 |
11 | 1500 | 163.46 | 34.531 | 34.62 | 3.61 | 2.43 | < 0.02 | < 0.02 | 76.38 |
10 | 1751.4 | 158.50 | 34.592 | 35.49 | 2.93 | 2.51 | < 0.02 | < 0.02 | 91.26 |
9 | 2001 | 166.54 | 34.643 | 34.81 | 2.52 | 2.46 | < 0.02 | < 0.02 | 93.03 |
8 | 2250.3 | 174.49 | 34.680 | 34.08 | 2.28 | 2.40 | < 0.02 | < 0.02 | 94.95 |
7 | 2500.6 | 183.38 | 34.710 | 33.13 | 2.09 | 2.33 | < 0.02 | < 0.02 | 95.43 |
6 | 2750.2 | 189.01 | 34.724 | 32.82 | 1.88 | 2.31 | < 0.02 | < 0.02 | 100.08 |
5 | 3001 | 192.94 | 34.727 | 32.77 | 1.70 | 2.31 | < 0.02 | < 0.02 | 105.04 |
4 | 3501.2 | 199.14 | 34.722 | 33.07 | 1.35 | 2.32 | < 0.02 | < 0.02 | 114.07 |
3 | 4001.1 | 201.64 | 34.717 | 33.31 | 1.19 | 2.34 | < 0.02 | < 0.02 | 119.14 |
2 | 4499.6 | 202.45 | 34.715 | 33.43 | 1.19 | 2.35 | < 0.02 | < 0.02 | 120.77 |
1 | 4924.5 | 203.56 | 34.713 | 33.38 | 1.19 | 2.35 | < 0.02 | < 0.02 | 121.79 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |