Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-14 12:18 to 2018-09-14 14:06 UTC
Where: 35° 57.1' S 152° 52.6' E
Maximum Depth (m): 1502.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 19.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.4 | 228.89 | 35.746 | 1.38 | 19.31 | 0.18 | < 0.02 | 0.39 | 0.71 |
34 | 15.5 | < 0.02 | < 0.02 | < 0.02 | 19.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 15.7 | < 0.02 | < 0.02 | 1.38 | 19.31 | 0.19 | 0.02 | 0.39 | 0.71 |
31 | 29.9 | < 0.02 | < 0.02 | 1.38 | 19.32 | 0.18 | < 0.02 | 0.39 | 0.71 |
32 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 19.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 19.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 40.6 | < 0.02 | < 0.02 | 1.39 | 19.32 | 0.18 | 0.03 | 0.39 | 0.69 |
27 | 49 | < 0.02 | < 0.02 | 1.38 | 19.33 | 0.18 | < 0.02 | 0.39 | 0.70 |
28 | 49.3 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 59.7 | < 0.02 | < 0.02 | 1.39 | 19.33 | 0.19 | < 0.02 | 0.39 | 0.71 |
26 | 59.7 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 70 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 70.1 | < 0.02 | < 0.02 | 1.38 | 19.33 | 0.18 | < 0.02 | 0.39 | 0.73 |
21 | 100.3 | 229.02 | 35.746 | 1.39 | 19.33 | 0.19 | < 0.02 | 0.39 | 0.71 |
22 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 124.6 | < 0.02 | < 0.02 | 1.39 | 19.34 | 0.19 | 0.02 | 0.40 | 0.71 |
20 | 124.7 | < 0.02 | < 0.02 | < 0.02 | 19.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 149.4 | < 0.02 | < 0.02 | 1.48 | 19.33 | 0.19 | < 0.02 | 0.43 | 0.72 |
18 | 149.4 | < 0.02 | < 0.02 | < 0.02 | 19.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 200.5 | < 0.02 | < 0.02 | 1.70 | 19.31 | 0.20 | < 0.02 | 0.38 | 0.75 |
15 | 221.1 | < 0.02 | < 0.02 | 3.70 | 18.83 | 0.33 | < 0.02 | 0.04 | 1.12 |
14 | 301.4 | 207.00 | 35.591 | 5.42 | 17.33 | 0.45 | < 0.02 | 0.02 | 1.66 |
13 | 401.2 | 199.10 | 35.280 | 10.59 | 14.29 | 0.78 | < 0.02 | < 0.02 | 3.50 |
12 | 502.5 | 207.50 | 35.051 | 13.97 | 11.92 | 1.00 | < 0.02 | < 0.02 | 5.06 |
11 | 601.5 | 232.91 | 35.286 | 9.32 | 12.22 | 0.73 | < 0.02 | < 0.02 | 3.39 |
10 | 701.2 | < 0.02 | < 0.02 | 14.86 | 10.62 | 1.07 | < 0.02 | < 0.02 | 6.04 |
9 | 799.9 | 208.61 | 34.612 | 22.14 | 8.49 | 1.51 | < 0.02 | < 0.02 | 11.10 |
8 | 899.9 | 203.39 | 34.520 | 25.11 | 7.42 | 1.71 | < 0.02 | < 0.02 | 16.65 |
7 | 999.3 | < 0.02 | < 0.02 | 27.62 | 6.46 | 1.89 | < 0.02 | < 0.02 | 23.75 |
6 | 1099.5 | 193.56 | 34.446 | 29.34 | 5.79 | 2.01 | < 0.02 | < 0.02 | 31.52 |
5 | 1200.4 | < 0.02 | < 0.02 | 31.15 | 5.07 | 2.15 | < 0.02 | < 0.02 | 42.49 |
4 | 1300 | 178.33 | 34.469 | 32.66 | 4.45 | 2.27 | < 0.02 | < 0.02 | 54.42 |
3 | 1401.5 | < 0.02 | < 0.02 | 33.73 | 4.01 | 2.35 | < 0.02 | < 0.02 | 65.88 |
2 | 1502.2 | < 0.02 | < 0.02 | < 0.02 | 3.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1502.2 | 163.59 | 34.532 | 34.62 | 3.58 | 2.44 | < 0.02 | < 0.02 | 76.97 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |