Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-13 12:24 to 2018-09-13 17:05 UTC
Where: 37° 22.8' S 150° 53.7' E
Maximum Depth (m): 4732
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
33 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.6 | 244.65 | 35.665 | 1.47 | 17.67 | 0.23 | 0.06 | 0.20 | 1.05 |
28 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 15.1 | < 0.02 | < 0.02 | 1.48 | 17.67 | 0.23 | 0.06 | 0.20 | 1.07 |
26 | 30.5 | < 0.02 | < 0.02 | 1.79 | 17.63 | 0.25 | 0.13 | 0.24 | 1.08 |
25 | 39.6 | < 0.02 | < 0.02 | 2.52 | 17.54 | 0.30 | 0.25 | 0.31 | 1.24 |
24 | 49.6 | < 0.02 | < 0.02 | 4.35 | 16.72 | 0.41 | 0.06 | 0.39 | 1.59 |
23 | 60.1 | < 0.02 | < 0.02 | 4.42 | 16.46 | 0.41 | < 0.02 | 0.39 | 1.64 |
22 | 68.9 | < 0.02 | < 0.02 | 5.03 | 16.33 | 0.45 | < 0.02 | 0.29 | 1.81 |
21 | 99 | 208.70 | 35.414 | 8.28 | 15.13 | 0.65 | < 0.02 | 0.03 | 2.71 |
20 | 124.3 | < 0.02 | < 0.02 | 6.65 | 15.16 | 0.55 | < 0.02 | 0.03 | 2.21 |
19 | 149.8 | < 0.02 | < 0.02 | 9.61 | 14.28 | 0.73 | < 0.02 | 0.02 | 3.21 |
18 | 200.5 | < 0.02 | < 0.02 | 10.63 | 13.40 | 0.80 | < 0.02 | < 0.02 | 3.61 |
17 | 300.1 | 207.05 | 34.869 | 17.05 | 10.64 | 1.19 | < 0.02 | < 0.02 | 6.44 |
16 | 501.6 | 206.91 | 34.598 | 22.86 | 8.21 | 1.58 | < 0.02 | < 0.02 | 12.29 |
15 | 751.1 | 196.33 | 34.449 | 28.56 | 6.08 | 1.97 | < 0.02 | < 0.02 | 27.31 |
14 | 1000.3 | 181.28 | 34.462 | 32.09 | 4.66 | 2.24 | < 0.02 | < 0.02 | 50.19 |
13 | 1250.4 | 165.96 | 34.522 | 34.40 | 3.66 | 2.43 | < 0.02 | < 0.02 | 73.97 |
12 | 1400.5 | 158.86 | 34.563 | 35.26 | 3.20 | 2.47 | < 0.02 | < 0.02 | 85.92 |
11 | 1600.9 | 160.73 | 34.602 | 35.33 | 2.79 | 2.49 | < 0.02 | < 0.02 | 91.29 |
10 | 1751.3 | 163.73 | 34.634 | 35.10 | 2.56 | 2.48 | < 0.02 | < 0.02 | 94.44 |
9 | 2001 | 172.17 | 34.672 | 34.23 | 2.31 | 2.42 | < 0.02 | < 0.02 | 94.91 |
8 | 2250.7 | 181.15 | 34.702 | 33.41 | 2.12 | 2.34 | < 0.02 | < 0.02 | 95.08 |
7 | 2501.6 | 186.95 | 34.718 | 32.94 | 1.95 | 2.31 | < 0.02 | < 0.02 | 98.36 |
6 | 2750.6 | 190.61 | 34.725 | 32.84 | 1.79 | 2.30 | < 0.02 | < 0.02 | 102.67 |
5 | 3000.2 | 194.50 | 34.727 | 32.82 | 1.63 | 2.29 | < 0.02 | < 0.02 | 106.85 |
4 | 3499.6 | 200.35 | 34.721 | 33.12 | 1.31 | 2.32 | < 0.02 | < 0.02 | 115.28 |
3 | 4000.8 | 202.14 | 34.715 | 33.32 | 1.17 | 2.33 | < 0.02 | < 0.02 | 119.88 |
2 | 4501.2 | 203.74 | 34.713 | 33.36 | 1.15 | 2.34 | < 0.02 | < 0.02 | 121.92 |
1 | 4732 | 205.75 | 34.712 | 33.27 | 1.13 | 2.34 | 0.02 | < 0.02 | 122.42 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |