Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-13 08:06 to 2018-09-13 09:59 UTC
Where: 37° 22.9' S 150° 53.9' E
Maximum Depth (m): 1502.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.9 | 245.77 | 35.662 | 1.56 | 17.74 | 0.22 | 0.03 | 0.21 | 1.09 |
36 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 17.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 15 | < 0.02 | < 0.02 | 1.67 | 17.64 | 0.23 | 0.05 | 0.22 | 1.10 |
34 | 15.1 | < 0.02 | < 0.02 | < 0.02 | 17.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 29.9 | < 0.02 | < 0.02 | 1.90 | 17.61 | 0.24 | 0.08 | 0.25 | 1.13 |
32 | 30 | < 0.02 | < 0.02 | < 0.02 | 17.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 40.4 | < 0.02 | < 0.02 | 2.29 | 17.28 | 0.27 | 0.18 | 0.33 | 1.19 |
30 | 40.4 | < 0.02 | < 0.02 | < 0.02 | 17.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 50.2 | < 0.02 | < 0.02 | 3.83 | 16.92 | 0.36 | 0.02 | 0.41 | 1.52 |
25 | 59.7 | < 0.02 | < 0.02 | 5.52 | 16.39 | 0.46 | < 0.02 | 0.30 | 1.99 |
26 | 59.7 | < 0.02 | < 0.02 | < 0.02 | 16.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 69.5 | < 0.02 | < 0.02 | < 0.02 | 15.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 69.7 | < 0.02 | < 0.02 | 7.81 | 15.54 | 0.61 | < 0.02 | 0.06 | 2.66 |
22 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 15.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 100.4 | 210.89 | 35.414 | 8.26 | 15.02 | 0.64 | < 0.02 | 0.03 | 2.72 |
20 | 123.7 | < 0.02 | < 0.02 | < 0.02 | 14.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 123.7 | < 0.02 | < 0.02 | 7.52 | 14.98 | 0.59 | < 0.02 | 0.03 | 2.52 |
18 | 149.6 | < 0.02 | < 0.02 | < 0.02 | 14.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 149.7 | < 0.02 | < 0.02 | 9.37 | 14.49 | 0.70 | < 0.02 | 0.03 | 3.16 |
16 | 199.8 | < 0.02 | < 0.02 | < 0.02 | 12.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 199.8 | < 0.02 | < 0.02 | 12.81 | 12.59 | 0.92 | < 0.02 | 0.02 | 4.55 |
14 | 301.2 | 206.65 | 34.853 | 17.32 | 10.54 | 1.20 | < 0.02 | < 0.02 | 6.63 |
13 | 498.9 | 207.05 | 34.565 | 23.06 | 8.14 | 1.57 | < 0.02 | < 0.02 | 12.17 |
12 | 600.2 | 203.79 | 34.497 | 25.57 | 7.19 | 1.75 | < 0.02 | < 0.02 | 17.36 |
11 | 701.1 | 200.13 | 34.465 | 27.31 | 6.54 | 1.87 | < 0.02 | < 0.02 | 22.63 |
10 | 801.3 | < 0.02 | < 0.02 | 28.88 | 5.92 | 1.98 | < 0.02 | < 0.02 | 29.44 |
9 | 1000.5 | 184.36 | 34.460 | 31.78 | 4.78 | 2.20 | < 0.02 | < 0.02 | 48.20 |
8 | 1101.1 | 216.43 | 34.484 | 33.19 | 4.21 | 2.31 | < 0.02 | < 0.02 | 60.04 |
7 | 1150.8 | < 0.02 | < 0.02 | 33.85 | 3.92 | 2.36 | < 0.02 | < 0.02 | 66.65 |
6 | 1199 | 168.19 | 34.513 | 34.21 | 3.76 | 2.39 | < 0.02 | < 0.02 | 70.83 |
5 | 1249.2 | < 0.02 | < 0.02 | 34.50 | 3.63 | 2.41 | < 0.02 | < 0.02 | 74.69 |
4 | 1301 | 164.35 | 34.537 | 34.78 | 3.48 | 2.43 | < 0.02 | < 0.02 | 78.74 |
3 | 1351.3 | < 0.02 | < 0.02 | 35.02 | 3.33 | 2.46 | < 0.02 | < 0.02 | 82.89 |
2 | 1401.8 | 161.85 | 34.564 | 35.23 | 3.19 | 2.48 | < 0.02 | < 0.02 | 86.11 |
1 | 1502.5 | 160.29 | 34.585 | 35.39 | 2.95 | 2.49 | < 0.02 | < 0.02 | 89.64 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |