Deployment Details
Survey: - IN2018_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - CTD 24 - SN 70111,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer
When: 2018-09-12 10:32 to 2018-09-12 12:27 UTC
Where: 39° 08.5' S 149° 04.6' E
Maximum Depth (m): 1683
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
28 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 4.8 | 266.31 | 35.492 | 3.56 | 14.06 | 0.37 | 0.06 | 0.18 | 1.25 |
36 | 5 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 14.4 | < 0.02 | < 0.02 | 3.56 | 14.06 | 0.36 | 0.06 | 0.17 | 1.27 |
25 | 30.5 | < 0.02 | < 0.02 | 3.61 | 14.06 | 0.37 | 0.06 | 0.18 | 1.31 |
24 | 30.6 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 40 | < 0.02 | < 0.02 | 3.57 | 14.06 | 0.36 | 0.06 | 0.17 | 1.28 |
22 | 50.9 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 51 | < 0.02 | < 0.02 | 3.62 | 14.06 | 0.36 | 0.06 | 0.18 | 1.30 |
20 | 59.4 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 59.5 | < 0.02 | < 0.02 | 3.92 | 14.06 | 0.40 | 0.06 | 0.18 | 1.37 |
17 | 70 | < 0.02 | < 0.02 | 6.11 | 13.84 | 0.53 | 0.04 | 0.23 | 1.92 |
18 | 70 | < 0.02 | < 0.02 | < 0.02 | 13.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 98.9 | < 0.02 | < 0.02 | < 0.02 | 13.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 98.9 | 250.15 | 35.442 | 6.67 | 13.63 | 0.55 | < 0.02 | 0.05 | 2.06 |
14 | 125 | < 0.02 | < 0.02 | 6.67 | 13.62 | 0.55 | < 0.02 | 0.05 | 2.10 |
13 | 151 | < 0.02 | < 0.02 | < 0.02 | 13.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 151.1 | < 0.02 | < 0.02 | 6.78 | 13.58 | 0.56 | < 0.02 | 0.06 | 2.12 |
10 | 201 | < 0.02 | < 0.02 | 6.49 | 13.56 | 0.55 | < 0.02 | 0.15 | 2.04 |
11 | 201 | < 0.02 | < 0.02 | < 0.02 | 13.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 301.4 | 251.80 | 35.441 | 6.51 | 13.52 | 0.55 | < 0.02 | 0.13 | 2.02 |
8 | 501.3 | 226.43 | 34.895 | 15.35 | 10.50 | 1.10 | < 0.02 | < 0.02 | 5.21 |
7 | 750.6 | 200.39 | 34.480 | 26.59 | 6.90 | 1.82 | < 0.02 | < 0.02 | 19.70 |
6 | 1000.7 | 187.89 | 34.444 | 30.93 | 5.13 | 2.14 | 0.02 | < 0.02 | 40.23 |
5 | 1100.7 | 181.64 | 34.460 | 32.06 | 4.70 | 2.25 | < 0.02 | < 0.02 | 49.27 |
4 | 1251.2 | 171.77 | 34.499 | 33.81 | 3.93 | 2.38 | < 0.02 | < 0.02 | 65.07 |
3 | 1501.3 | 162.12 | 34.566 | 35.13 | 3.10 | 2.50 | 0.07 | < 0.02 | 83.96 |
2 | 1600 | 163.24 | 34.610 | 35.09 | 2.73 | 2.49 | < 0.02 | < 0.02 | 89.68 |
1 | 1683 | < 0.02 | 34.639 | 34.70 | 2.51 | 2.45 | < 0.02 | < 0.02 | 91.03 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |