Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 95
Gear: Autosal Salinometer,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24 - SN 4522,Temperature CTD 24 - SN 6180,Transmissometer - CTD 24 -CST-1421DR
When: 2018-02-12 20:29 to 2018-02-12 20:55 UTC
Where: 64° 58.8' S 132° 03.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 7.3 | < 0.02 | < 0.02 | < 0.02 | -1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 7.5 | 356.93 | 33.679 | 26.45 | -1.02 | 1.87 | 0.91 | 0.13 | 51.19 |
34 | 39 | 354.74 | 33.744 | 26.76 | -1.09 | 1.90 | 0.90 | 0.13 | 51.83 |
33 | 39.1 | < 0.02 | < 0.02 | < 0.02 | -1.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 90.7 | < 0.02 | < 0.02 | < 0.02 | -1.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 90.7 | 337.01 | 34.149 | 29.49 | -1.69 | 2.10 | 0.68 | 0.11 | 56.81 |
21 | 120.7 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 120.8 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 120.8 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 120.9 | 328.04 | 34.229 | 30.85 | -1.79 | 2.15 | 0.12 | 0.12 | 58.30 |
24 | 120.9 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 120.9 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 120.9 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 121 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 121 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 121 | < 0.02 | < 0.02 | < 0.02 | -1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 160.2 | < 0.02 | < 0.02 | < 0.02 | -1.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 160.3 | < 0.02 | < 0.02 | < 0.02 | -1.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 160.3 | < 0.02 | < 0.02 | < 0.02 | -1.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 160.4 | < 0.02 | < 0.02 | < 0.02 | -1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 160.4 | < 0.02 | < 0.02 | < 0.02 | -1.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 160.4 | < 0.02 | < 0.02 | < 0.02 | -1.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 160.5 | < 0.02 | < 0.02 | < 0.02 | -1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 160.5 | 322.68 | 34.273 | 31.28 | -1.76 | 2.16 | 0.03 | 0.07 | 61.01 |
5 | 229.4 | < 0.02 | < 0.02 | < 0.02 | -1.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 229.4 | < 0.02 | < 0.02 | < 0.02 | -1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 229.4 | < 0.02 | < 0.02 | < 0.02 | -1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 229.4 | < 0.02 | < 0.02 | < 0.02 | -1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 229.5 | < 0.02 | < 0.02 | < 0.02 | -1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 229.5 | < 0.02 | < 0.02 | < 0.02 | -1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 229.5 | 309.19 | 34.403 | 31.77 | -1.48 | 2.21 | < 0.02 | 0.03 | 68.88 |
10 | 229.6 | < 0.02 | < 0.02 | < 0.02 | -1.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 284.1 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 284.2 | 317.45 | 34.448 | 31.89 | -1.60 | 2.21 | < 0.02 | 0.05 | 69.22 |
2 | 284.3 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 284.3 | < 0.02 | < 0.02 | < 0.02 | -1.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |