Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-03-08 13:24 to 2018-03-08 15:12 UTC
Where: 46° 59.8' S 142° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 5.3 | 276.81 | 34.663 | 7.86 | 11.93 | 0.68 | 0.06 | 0.17 | 0.57 |
2036 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 11.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 24.7 | 276.63 | 34.684 | 7.58 | 11.95 | 0.66 | 0.08 | 0.17 | 0.56 |
2034 | 25.2 | < 0.02 | < 0.02 | 7.54 | 11.94 | 0.66 | 0.08 | 0.17 | 0.55 |
32 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 11.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 49.4 | 275.92 | 34.662 | 7.93 | 11.73 | 0.69 | 0.10 | 0.18 | 0.57 |
2030 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 11.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 75.7 | 272.16 | 34.697 | 7.61 | 11.75 | 0.68 | 0.24 | 0.18 | 0.55 |
2028 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 11.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 100 | 269.48 | 34.689 | 8.53 | 11.76 | 0.74 | 0.30 | 0.21 | 0.86 |
2026 | 125.5 | 263.10 | 34.713 | 14.03 | 9.87 | 1.04 | < 0.02 | 0.02 | 3.63 |
2025 | 150.9 | < 0.02 | < 0.02 | 13.81 | 9.87 | 1.03 | < 0.02 | 0.02 | 3.75 |
2024 | 150.9 | < 0.02 | < 0.02 | < 0.02 | 9.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 150.9 | 262.92 | 34.734 | 14.05 | 9.86 | 1.04 | < 0.02 | 0.02 | 3.78 |
2022 | 175.6 | 268.41 | 34.600 | 15.33 | 9.16 | 1.12 | < 0.02 | 0.02 | 4.26 |
2021 | 199.8 | < 0.02 | < 0.02 | 15.02 | 9.23 | 1.10 | < 0.02 | 0.02 | 4.04 |
2020 | 199.8 | 269.17 | 34.624 | 15.02 | 9.23 | 1.10 | < 0.02 | 0.02 | 4.06 |
2019 | 250.1 | 265.38 | 34.676 | 14.91 | 9.32 | 1.09 | < 0.02 | 0.02 | 4.04 |
2015 | 300.7 | 262.20 | 34.715 | 14.83 | 9.50 | 1.08 | < 0.02 | < 0.02 | 4.00 |
2016 | 300.7 | < 0.02 | < 0.02 | < 0.02 | 9.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 300.8 | < 0.02 | < 0.02 | 14.86 | 9.50 | 1.08 | < 0.02 | 0.02 | 4.00 |
2017 | 300.9 | < 0.02 | < 0.02 | < 0.02 | 9.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 351.6 | 258.68 | 34.662 | 16.02 | 9.18 | 1.16 | < 0.02 | < 0.02 | 4.54 |
2013 | 450.5 | < 0.02 | < 0.02 | < 0.02 | 8.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 500.3 | < 0.02 | < 0.02 | 16.40 | 8.78 | 1.19 | < 0.02 | < 0.02 | 4.55 |
2012 | 500.4 | < 0.02 | < 0.02 | < 0.02 | 8.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 500.4 | < 0.02 | < 0.02 | 16.39 | 8.78 | 1.19 | < 0.02 | < 0.02 | 4.58 |
2009 | 601.4 | 249.48 | 34.538 | 19.28 | 8.32 | 1.37 | < 0.02 | < 0.02 | 6.77 |
2008 | 700.6 | < 0.02 | < 0.02 | < 0.02 | 7.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 799.6 | 219.96 | 34.388 | 26.56 | 6.41 | 1.83 | < 0.02 | < 0.02 | 16.99 |
2006 | 1000.9 | 218.35 | 34.314 | 30.41 | 4.73 | 2.10 | < 0.02 | < 0.02 | 27.82 |
2005 | 1199.9 | 195.08 | 34.387 | 33.17 | 3.87 | 2.32 | < 0.02 | < 0.02 | 47.10 |
12004 | 1399.7 | 185.48 | 34.444 | 34.78 | 3.10 | 2.43 | < 0.02 | < 0.02 | 58.82 |
12003 | 1600.4 | 177.53 | 34.534 | 34.89 | 2.81 | 2.43 | < 0.02 | < 0.02 | 69.43 |
12002 | 1799.8 | 176.23 | 34.620 | 34.22 | 2.61 | 2.39 | < 0.02 | < 0.02 | 77.31 |
12001 | 2000.6 | 177.57 | 34.675 | 33.65 | 2.44 | 2.35 | < 0.02 | < 0.02 | 83.77 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |