Deployment Details
Survey: - IN2017_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 27
Gear: Autosal Salinometer,CTD 20 - SN 1312,CTD 24 - SN 1332,Conductivity CTD 24 - SN 4685,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20 - SN 3534,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 6189,Temperature CTD 24 - SN 6180,Transmissometer
When: 2017-09-11 23:28 to 2017-09-12 00:19 UTC
Where: 34° 41.8' S 153° 15.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2032 | 8.1 | 257.52 | 35.586 | 2.54 | 16.09 | 0.35 | 0.54 | 0.55 | 1.04 |
2033 | 8.2 | < 0.02 | < 0.02 | < 0.02 | 16.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 16.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 16.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 26 | < 0.02 | < 0.02 | < 0.02 | 16.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 26 | < 0.02 | < 0.02 | < 0.02 | 16.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 26 | < 0.02 | < 0.02 | < 0.02 | 16.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 26 | 255.33 | 35.565 | 2.71 | 16.00 | 0.31 | 0.02 | 0.61 | 1.11 |
2023 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 50.6 | 251.40 | 35.579 | 3.02 | 15.96 | 0.32 | 0.02 | 0.68 | 1.16 |
2026 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 75.4 | 249.25 | 35.576 | 3.23 | 15.95 | 0.33 | < 0.02 | 0.74 | 1.26 |
2020 | 75.4 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 75.6 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 101.4 | 248.63 | 35.577 | 3.28 | 15.95 | 0.34 | < 0.02 | 0.74 | 1.26 |
2015 | 101.5 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 101.5 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 101.6 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 199.5 | < 0.02 | < 0.02 | < 0.02 | 14.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 199.6 | < 0.02 | < 0.02 | < 0.02 | 14.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 199.7 | < 0.02 | < 0.02 | < 0.02 | 14.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 199.7 | 208.30 | 35.303 | 9.95 | 14.44 | 0.75 | 0.03 | 0.17 | 3.84 |
2005 | 300.5 | 202.31 | 34.640 | 22.06 | 8.75 | 1.52 | < 0.02 | 0.02 | 11.69 |
1201 | 300.6 | < 0.02 | < 0.02 | < 0.02 | 8.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 501.4 | 195.84 | 34.450 | 28.71 | 6.01 | 1.98 | < 0.02 | < 0.02 | 28.52 |
12004 | 501.5 | < 0.02 | < 0.02 | < 0.02 | 6.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 1001.5 | 168.91 | 34.504 | 34.03 | 3.85 | 2.38 | < 0.02 | < 0.02 | 68.56 |
12002 | 1001.9 | < 0.02 | < 0.02 | < 0.02 | 3.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 1312 | Seabird | SBE9+ V_2 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |