Please login if you have access to particular applications.
Deployment Details
Survey: - IN2017_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 26
Gear: Autosal Salinometer,CTD 20 - SN 1312,CTD 24 - SN 1332,Conductivity CTD 24 - SN 4685,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20 - SN 3534,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 6189,Temperature CTD 24 - SN 6180,Transmissometer
When: 2017-09-11 18:59 to 2017-09-11 19:51 UTC
Where: 34° 50.6' S 153° 05.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 2029 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2026 | 6.1 | 250.64 | 35.600 | 2.77 | 16.13 | 0.31 | 0.02 | 0.54 | 0.88 |
| 2031 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2034 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2033 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2035 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2028 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2027 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2032 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2025 | 25.6 | 250.24 | 35.599 | 2.81 | 16.13 | 0.31 | 0.02 | 0.55 | 0.90 |
| 2023 | 25.7 | < 0.02 | < 0.02 | < 0.02 | 16.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2022 | 49.7 | < 0.02 | 35.596 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2017 | 49.7 | < 0.02 | < 0.02 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2015 | 49.8 | 248.32 | 35.597 | 3.16 | 16.09 | 0.33 | < 0.02 | 0.63 | 1.01 |
| 2021 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2016 | 50 | < 0.02 | < 0.02 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2019 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2020 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 16.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 75.1 | < 0.02 | < 0.02 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2013 | 75.1 | 246.31 | 35.594 | 3.20 | 16.08 | 0.33 | 0.02 | 0.64 | 1.06 |
| 2036 | 100.2 | 246.75 | 35.596 | 3.14 | 16.08 | 0.32 | < 0.02 | 0.62 | 1.04 |
| 2011 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 16.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2008 | 200.6 | 194.45 | 35.173 | 12.86 | 13.49 | 0.92 | < 0.02 | 0.03 | 4.58 |
| 2009 | 200.7 | < 0.02 | < 0.02 | < 0.02 | 13.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2005 | 300.1 | 206.78 | 34.686 | 20.62 | 9.21 | 1.41 | < 0.02 | < 0.02 | 8.93 |
| 1201 | 300.2 | < 0.02 | < 0.02 | < 0.02 | 9.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12003 | 501.3 | 200.17 | 34.477 | 26.91 | 6.76 | 1.84 | < 0.02 | < 0.02 | 20.93 |
| 12004 | 501.7 | < 0.02 | < 0.02 | < 0.02 | 6.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12001 | 1005.9 | 171.05 | 34.495 | 33.79 | 4.02 | 2.35 | < 0.02 | < 0.02 | 64.99 |
| 12002 | 1005.9 | < 0.02 | < 0.02 | < 0.02 | 4.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CTD 20 - SN 1312 | Seabird | SBE9+ V_2 | 1312 | |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
| Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 20 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
| Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 20 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
| Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |