Survey | When (UTC) | Latitude | Longitude | Instrument | Identifier | Action | Log | Subject / Comments |
---|---|---|---|---|---|---|---|---|
IN2016_E01 | 2016-08-19 04:50 [view ] | -43.8097 | 150.5881 | CCN [view] | maintenance | in2016_e01 | Extended milli-Q intake tube for instrument Requested by Aspendale folks | |
IN2016_V04 | 2016-09-03 14:00 [view ] | -34.1168 | 151.6416 | CCN [view] | restarted | in2016_v04 | after aerosol lab power outage MAAP and Ozone also down since ~0200 | |
IN2017_T01 | 2017-09-27 20:50 [view ] | -19.9836 | 153.2950 | CCN [view] | restarted | in2017_t01 | No particle count - Status Reset | |
IN2017_T01 | 2017-09-28 20:39 [view ] | -15.9367 | 150.9888 | CCN [view] | restarted | in2017_t01 | No particle count - Status Reset | |
IN2017_T01 | 2017-09-29 17:10 [view ] | -13.2191 | 147.9719 | CCN [view] | restarted | in2017_t01 | No particle count - Status Reset | |
IN2017_T01 | 2017-10-01 18:07 [view ] | -10.6259 | 141.2415 | CCN [view] | restarted | in2017_t01 | Restarted after reset from No CCN counts error. | |
IN2017_V03 | 2017-06-06 23:04 [view ] | -29.5177 | 154.0490 | CCNC [view] | maintenance | in2017_v03 | CCNC MilliQ replaced CCNC MilliQ replaced and leak tested with filter | |
IN2017_V04 | 2017-09-13 05:26 [view ] | -35.1649 | 151.8718 | CCN [view] | maintenance | in2017_v04 | CCNC MilliQ replaced - yesterday Did this yesteday. No time to log. | |
IN2017_V05 | 2017-10-19 04:30 [view ] | -19.9998 | 117.0505 | CCN [view] | Start | in2017_v05 | CCNC started. MilliQ at 'full' level | |
IN2017_V05 | 2017-10-24 23:30 [view ] | -20.2657 | 116.3768 | CCN [view] | Stop | in2017_v05 | Turned off CCNC to let it warm up and (hopefully) unfreeze | |
IN2017_V05 | 2017-10-25 01:44 [view ] | -20.4433 | 116.2782 | CCN [view] | test | in2017_v05 | CCN restarted after a rest running on lab air (to dry out) | |
IN2018_T01 | 2018-04-12 23:30 [view ] | -31.3683 | 154.1238 | CCNC [view] | Stop | in2018_t01 | Stopped due to high humidity | |
IN2018_T01 | 2018-04-13 03:00 [view ] | -30.7582 | 154.1065 | CCNC [view] | Start | in2018_t01 | Turned back off | |
IN2018_T02 | 2018-05-20 20:00 [view ] | -43.0072 | 147.3807 | CCNC [view] | Stop | Atmospherics_in2018_t02 | End of voyage shutdown - standard shutdown only, not 'dry shutdown' | |
IN2018_V01 | 2018-01-19 21:59 [view ] | -51.4813 | 143.0195 | CCN [view] | Atmospherics in2018_v01 | Restarting measurements Measurements didn& 39;t autorestart after power outage. Started manually now. | ||
IN2018_V01 | 2018-02-04 00:32 [view ] | -65.5185 | 149.9083 | CCN [view] | Atmospherics in2018_v01 | Turned off for water refill and drain | ||
IN2018_V01 | 2018-02-04 00:46 [view ] | -65.5181 | 149.9099 | CCN [view] | Atmospherics in2018_v01 | Back on after successful zero | ||
IN2018_V01 | 2018-02-05 00:21 [view ] | -64.3013 | 150.0037 | CCN [view] | Atmospherics in2018_v01 | Adjusted flow ratio from 9.7 to 10.0 | ||
IN2018_V01 | 2018-02-11 05:03 [view ] | -62.5003 | 132.0500 | CCN [view] | Atmospherics in2018_v01 | Taken offline for zero and flow check for 2 minutes Flow 486.1 Zero OK | ||
IN2018_V01 | 2018-02-16 04:57 [view ] | -57.9207 | 131.9820 | CCN [view] | Atmospherics in2018_v01 | Taken offline for zero and flow check Zero OK Flow 464 ccm | ||
IN2018_V01 | 2018-02-17 01:39 [view ] | -56.8412 | 134.9502 | CCN [view] | Atmospherics in2018_v01 | Turned off for water refill and drain | ||
IN2018_V01 | 2018-02-21 20:25 [view ] | -42.9358 | 147.3882 | CCN [view] | Atmospherics in2018_v01 | Final flow and zero checks Inlet flow: 479 Inlet flow (inline with manifold): 484 Zero OK | ||
IN2018_V04 | 2018-09-21 22:55 [view ] | -40.1268 | 153.4420 | CCNC [view] | Maintenance | Atmospherics_in2018_v04 | Replenished MilliQ | |
IN2018_V04 | 2018-10-06 05:00 [view ] | -45.9565 | 143.4602 | CCNC [view] | Maintenance | Atmospherics_in2018_v04 | Recharged Miliq | |
IN2018_V05 | 2018-10-24 12:12 [view ] | -55.6560 | 150.7570 | CCNC [view] | Maintenance | Atmospherics_in2018_v05 | fill milli q and zero check | |
IN2018_V05 | 2018-11-04 05:21 [view ] | -56.1428 | 154.3812 | CCNC [view] | Maintenance | Atmospherics_in2018_v05 | HEPA filter weekly ZERO check Zero check successful - <5 or better particales after a minute | |
IN2018_V05 | 2018-11-06 07:08 [view ] | -56.7362 | 155.1942 | CCNC [view] | Maintenance | Atmospherics_in2018_v05 | Drain milliq - HEPA checked okay <3 particles | |
IN2018_V05 | 2018-11-12 08:58 [view ] | -55.5277 | 152.0083 | CCNC [view] | Maintenance | Atmospherics_in2018_v05 | millie-q fill and HEPA check | |
IN2018_V05 | 2018-11-14 17:33 [view ] | -46.1777 | 148.7932 | CCNC [view] | Maintenance | Atmospherics_in2018_v05 | Put cover back on instrument. Had to disconnect bottles momentarily. Possible air bubble introduction? | |
IN2018_V06 | 2018-12-07 03:27 [view ] | -44.2317 | 146.1713 | CCNC [view] | Maintenance | in2018_v06_Atmospherics | millie-q fill and HEPA check HEPA check ~2 | |
IN2019_E01 | 2019-07-21 10:18 [view ] | CCNC [view] | Maintenance | in2019_e01_Atmospherics | CCN calibration Set-up CCN calibration chassis. Power on CCNC, dry start up mode. All OK. | |||
IN2019_E01 | 2019-07-27 09:12 [view ] | CCNC [view] | Maintenance | in2019_e01_Atmospherics | supersaturation settting I had the CCNc in & 39;manual& 39; SS mode for a few hrs this afternoon. back on auto ss 09:15am | |||
IN2019_E01 | 2019-07-28 04:57 [view ] | -10.0657 | 135.7915 | CCNC [view] | Change | in2019_e01_Atmospherics | CCNc supersaturation SS set to manual mode 04:57UTC hrs | |
IN2019_E01 | 2019-07-28 06:38 [view ] | -10.1743 | 136.1368 | CCNC [view] | Change | in2019_e01_Atmospherics | supersaturation settting changed back to auto mode 06:30hrs | |
IN2019_E01 | 2019-07-28 21:51 [view ] | -11.0927 | 139.0580 | CCNC [view] | Change | in2019_e01_Atmospherics | Zero check and SS HEPA zero check 09:45- 09:50pm switched to manual SS 09:53hrs for todays SS calibration. | |
IN2019_E01 | 2019-07-29 05:11 [view ] | -10.9952 | 140.5470 | CCNC [view] | Change | in2019_e01_Atmospherics | supersaturation settting changed SS to deltaT = 14.0 (SS=0.97) at 05:10hrs | |
IN2019_E01 | 2019-07-29 10:23 [view ] | -10.7560 | 141.5998 | CCNC [view] | Maintenance | in2019_e01_Atmospherics | CCN cal finished, set back to auto sampling, connected back up to main inlet CCN tap was also open, so this is now the start of proper ambient sampling on that line. | |
IN2019_E01 | 2019-07-29 23:57 [view ] | -9.3263 | 143.7108 | CCNC [view] | Change | in2019_e01_Atmospherics | supersaturation settting SS setting control was still in & 39;manual& 39; mode, after yesterdays calibration (SS= 0.09%, Dt= 3.0). Switched to Auto SS 12:00am UTC | |
IN2019_E01 | 2019-08-02 00:08 [view ] | -16.8132 | 145.8402 | CCNC [view] | Maintenance | in2019_e01_Atmospherics | Empty drain, fill water supply, zero check. | |
IN2019_E01 | 2019-08-02 00:12 [view ] | -16.8240 | 145.8360 | CCNC [view] | Start | in2019_e01_Atmospherics | Resumed ambient sampling | |
IN2019_T01 | 2019-04-29 01:25 [view ] | -43.3657 | 147.4785 | CCNC [view] | Maintenance | in2019_t01_Atmospherics | mili q Refill | |
IN2019_T01 | 2019-05-01 02:18 [view ] | -38.6592 | 141.1313 | CCNC [view] | Maintenance | in2019_t01_Atmospherics | Adjusted sheath flow removed bottles and cover to make change, vavle didn& 39;t affect flow ratio - a problem somewhere | |
IN2019_T01 | 2019-05-01 21:01 [view ] | -38.9402 | 140.8993 | CCNC [view] | Fault | in2019_t01_Atmospherics | Sheath flow adjusted after seath filter replaced - flow ratio still low 8.5 | |
IN2019_T01 | 2019-05-04 20:39 [view ] | -37.7887 | 130.1133 | CCNC [view] | Stop | in2019_t01_Atmospherics | stopped to clean needle valve | |
IN2019_T01 | 2019-05-04 23:36 [view ] | -37.6730 | 129.4307 | CCNC [view] | Start | in2019_t01_Atmospherics | flow adjustment valve referbished valve removed and cleaned in the ultrasonic bath o-ring replaced, had visible sign of leaking pas seal surface-most likely cause of low flow problem flow ratio now 9.5 hepa zero test concestration now less than 1 - very good | |
IN2019_T01 | 2019-05-08 21:38 [view ] | -31.9402 | 115.5652 | CCNC [view] | Maintenance | in2019_t01_Atmospherics | milli-q fill and HEPA check | |
IN2019_T02 | 2019-10-14 00:41 [view ] | -12.4722 | 130.8460 | CCNC [view] | Maintenance | in2019_t02_Atmospherics | miliQ refill | |
IN2019_T03 | 2019-12-31 14:14 [view ] | -31.5695 | 115.1378 | CCNC [view] | Maintenance | in2019_t03_Atmospherics | Filled and emptied Milli-q | |
IN2019_V01 | 2019-01-26 15:56 [view ] | -64.7447 | 141.1780 | CCNC [view] | Maintenance | in2019_v01 | CCNC Miliq reservoir filled and waste emptied | |
IN2019_V01 | 2019-02-02 18:15 [view ] | -65.8128 | 144.3657 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | Miliq reservoir filled and waste emptied | |
IN2019_V01 | 2019-02-03 13:13 [view ] | -65.8578 | 144.1752 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | zero check after MQ fill | |
IN2019_V01 | 2019-02-04 19:00 [view ] | -65.7863 | 143.9250 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | Butanol Refill | |
IN2019_V01 | 2019-02-08 20:06 [view ] | -65.8650 | 146.9620 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | Miliq refill and empty drain bottle | |
IN2019_V01 | 2019-02-15 19:13 [view ] | -64.8528 | 149.6508 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | CCNC Miliq reservoir filled and waste emptied | |
IN2019_V01 | 2019-02-17 19:34 [view ] | -65.9437 | 148.2918 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | Butinol Refill | |
IN2019_V01 | 2019-02-23 01:11 [view ] | -65.7343 | 145.9687 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | butanol fill | |
IN2019_V01 | 2019-02-25 17:49 [view ] | -65.5450 | 149.3822 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | millie-q fill | |
IN2019_V01 | 2019-02-25 18:10 [view ] | -65.5538 | 149.5020 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | zero check after MQ fill | |
IN2019_V01 | 2019-03-02 16:43 [view ] | -48.2672 | 148.0027 | CCNC [view] | Maintenance | in2019_v01_Atmospherics | Butinol Refill and Cear Waste | |
IN2019_V03 | 2019-05-21 19:39 [view ] | -32.5830 | 110.0000 | CCNC [view] | in2019_v03_Atmospherics | Miliq refill and empty drain bottle | ||
IN2019_V03 | 2019-05-27 10:45 [view ] | -24.4913 | 109.9987 | CCNC [view] | Maintenance | in2019_v03_Atmospherics | Reinstall cover I reinstalled this cover. This required disconnecting the milli-q. | |
IN2019_V03 | 2019-05-27 10:46 [view ] | -24.4910 | 109.9985 | CCNC [view] | Maintenance | in2019_v03_Atmospherics | Zero check zero check following cover reinstallation | |
IN2019_V03 | 2019-05-29 00:28 [view ] | -21.5005 | 110.0003 | CCNC [view] | Maintenance | in2019_v03_Atmospherics | Butanol Refill | |
IN2019_V03 | 2019-06-01 19:26 [view ] | -16.0848 | 110.0000 | CCNC [view] | Maintenance | in2019_v03_Atmospherics | milli q filled | |
IN2019_V03 | 2019-06-12 08:20 [view ] | -28.4607 | 113.4815 | CCNC [view] | Stop | in2019_v03_Atmospherics | Dry Shut down for dry dock | |
IN2019_V04 | 2019-08-14 02:37 [view ] | -17.4880 | 155.8807 | CCNC [view] | Maintenance | in2019_v04_Atmospherics | CCNC - Milli-q Refilled Milli-q and emptied waste bottle | |
IN2019_V04 | 2019-08-26 02:37 [view ] | -14.0355 | 159.6465 | CCNC [view] | Maintenance | in2019_v04_Atmospherics | Filled and emptied Milli-q | |
IN2019_V05 | 2019-09-08 22:45 [view ] | -27.4158 | 153.1420 | CCNC [view] | Maintenance | in2019_v05_Atmospherics | Filled and emptied Milli-q | |
IN2019_V05 | 2019-09-21 01:00 [view ] | -27.2315 | 154.2045 | CCNC [view] | Maintenance | in2019_v05_Atmospherics | Milli-Q filled and emptied | |
IN2019_V06 | 2019-10-26 04:28 [view ] | -14.3495 | 121.3708 | CCNC [view] | Maintenance | in2019_v06_Atmospherics | Miliq topup Ruhi edited this instrument selection from SMPS to CCNC | |
IN2019_V06 | 2019-11-03 18:45 [view ] | -14.2133 | 121.3950 | CCNC [view] | Maintenance | in2019_v06_Atmospherics | Miliq refill | |
IN2019_V06 | 2019-11-16 00:32 [view ] | -11.2053 | 133.4437 | CCNC [view] | Maintenance | in2019_v06_Atmospherics | MilliQ filled Zero Check 0.0 | |
IN2019_V06 | 2019-11-26 05:15 [view ] | -12.3147 | 130.4092 | CCNC [view] | Change | in2019_v06_Atmospherics | Logged in remotely to change SS sequence Time: 26/11/2019 05:15 Ruhi Subject – Logged in remotely to change SS sequence Comments: Logged in remotely – instrument struggling with the remote connection and flows may be affected by CPU loading. Stopped measurement and closed software. Edited Table 1 of the SS sequence to reverse the order. Previous order was an hourly cycle of 6 SS, 10 min each 0.2, 0.3, 0.4, 0.5, 0.6, 1.0 New order is the reverse (10 min at each still): 1.0, 0.6, 0.5, 0.4, 0.3, 0.2. I have done this to try to improve the OPC temperature adherence – during the previous cycle, the transition from 1.0 to 0.2% doesn’t provide enough time for the OPC temperature to reach setpoint, creating a condition where the droplets may be evaporating in the OPC before detection. I have been advised that this may be improved by reversing the sequence (or doing a pyramid sequence, which is not ideal). | |
IN2019_V06 | 2019-12-10 23:07 [view ] | -12.3028 | 130.4230 | CCNC [view] | Maintenance | in2019_v06_Atmospherics | MilliQ filled Zero check ok (0-1) | |
IN2019_V06 | 2019-12-18 02:10 [view ] | CCNC [view] | Maintenance | in2019_v06_Atmospherics | Quarterly maintenance Sheath filter replaced. Desiccant tube inspected, looks good Sample flow calibration not possible - standard flow gilibrator cell not here (getting repaired) OPC water trap has no liquid MilliQ refilled HEPA zero good 0-1 | |||
IN2019_V07 | 2019-04-13 23:24 [view ] | -39.2328 | 146.6382 | CCNC [view] | Maintenance | Atmospherics_in2019_v07 | Empty drain, fill water supply | |
IN2019_V07 | 2019-04-13 23:24 [view ] | -39.2328 | 146.6382 | CCNC [view] | Maintenance | in2019_v07_Atmospherics | Empty drain, fill water supply | |
IN2020_T01 | 2020-03-13 06:25 [view ] | -32.0497 | 115.7450 | CCNC [view] | Maintenance | in2020_t01_Atmospherics | fluid fill | |
IN2020_V01 | 2020-01-20 01:57 [view ] | -55.1152 | 82.6637 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Fill/Emptied water CCNC | |
IN2020_V01 | 2020-01-30 05:41 [view ] | -53.5282 | 80.9838 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Fill/Emptied water CCNC | |
IN2020_V01 | 2020-02-07 20:23 [view ] | -52.8040 | 79.8558 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Stop data acqusition Stop data acqusition and control program, disconnect from the main sampling line (in preparation to change sheath flow filter). | |
IN2020_V01 | 2020-02-07 21:41 [view ] | -52.7693 | 79.9303 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Change sheath flow filter | |
IN2020_V01 | 2020-02-07 21:48 [view ] | -52.7622 | 79.9187 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Leak check Leak check performed after filter change, was successful | |
IN2020_V01 | 2020-02-07 22:17 [view ] | -52.7338 | 79.8643 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Zero check | |
IN2020_V01 | 2020-02-07 22:17 [view ] | -52.7335 | 79.8625 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Recconect to inlet maintainance complete | |
IN2020_V01 | 2020-02-07 22:18 [view ] | -52.7330 | 79.8602 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Fill/empty Milli-Q | |
IN2020_V01 | 2020-02-15 05:20 [view ] | -46.1232 | 85.5085 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Filled and emptied Milli-q | |
IN2020_V01 | 2020-02-21 05:58 [view ] | -32.5607 | 99.7317 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | Filled and emptied Milli-q | |
IN2020_V01 | 2020-03-05 15:57 [view ] | -31.9748 | 115.2428 | CCNC [view] | Maintenance | in2020_v01_Atmospherics | H20 Refill | |
IN2020_V06 | 2020-10-11 11:45 [view ] | -53.9127 | 159.2520 | CCNC [view] | Maintenance | in2020_v06_Atmospherics | Draind and filled milliQ | |
IN2020_V06 | 2020-10-24 00:32 [view ] | -55.1462 | 159.0585 | CCNC [view] | Maintenance | in2020_v06_Atmospherics | Topped up water. | |
IN2020_V06 | 2020-11-01 22:59 [view ] | -45.1945 | 150.1597 | CCNC [view] | Maintenance | in2020_v06_Atmospherics | MilliQ filled | |
IN2020_V08 | 2020-12-17 03:39 [view ] | -47.0988 | 141.3578 | CCNC [view] | Maintenance | Atmospherics_in2020_v08 | MilliQ filled | |
IN2020_V08 | 2021-01-02 14:50 [view ] | -58.0175 | 141.2688 | CCNC [view] | Maintenance | Atmospherics_in2020_v08 | MilliQ filled zero check good before and after filling | |
IN2020_V09 | 2020-09-11 21:15 [view ] | -44.6720 | 147.8128 | CCNC [view] | Maintenance | in2020_v09_Atmospherics | Filled and Emptied Milli-q | |
IN2020_V10 | 2020-11-19 05:32 [view ] | -44.1173 | 148.5893 | CCNC [view] | Maintenance | in2020_v10_Atmospherics | MilliQ filled | |
IN2021_E02 | 2021-11-23 01:16 [view ] | CCNC [view] | Maintenance | Atmospherics | SS Calibration incomplete Jason tried to undertake a supersaturation calibration on the RVI-CCNC with the calibration chassis. Major issues were encountered with the calibration setup rendering it unusable. No calibration was completed and no changes on the CCN undertaken. | |||
IN2021_T01 | 2021-06-12 23:23 [view ] | -20.6997 | 152.9645 | CCNC [view] | Start | Atmospherics | Startup following more repairs. drawing air from filter | |
IN2021_T01 | 2021-06-13 04:35 [view ] | -20.2587 | 152.1482 | CCNC [view] | Observation | Atmospherics | leak corrected, system appears working I think I have the CCNC working. Main repairs were: - to remove the contaminated tubing between the column solenoid pump, cold trap solenoid pump, and drain bottle. I also changed the column solenoid pump but in hindsight I don& 39;t think that was actually faulty. - The nafion humidifier tube was dry and coiled up inside the humidifier chamber. I had to really soak and stretch it to get it long enough to reinstall - The sheath flow filter and frit filter were saturated. I replaced the sheath flow filter and dried out the frit filter in the oven - on reassembly I had a leak or leaks. I tried almost all fittings as I had had most off. the final, and probably original leak i had was the connection to the tee at the upper side of the frit filter that goes to the sheath flow differential pressure sensor. The tubing had split slightly. I trimmed the end of the tube and remade the connection. All zeros!!!! | |
IN2021_T01 | 2021-06-13 04:47 [view ] | -20.2405 | 152.1198 | CCNC [view] | Start | Atmospherics | CCNC sampling from inlet following repairs (for real) Repairs seem stable. Flow rates were stable for >4hrs. Zero check has been successful for 15 mins. MilliQ topped up. System drawing from main inlet. . | |
IN2021_T01 | 2021-06-13 22:25 [view ] | -18.8068 | 149.6007 | CCNC [view] | Atmospherics | Logged in remotely to check - additional load on PC meant flows went bad temporarily | ||
IN2021_T01 | 2021-06-16 22:15 [view ] | -12.0758 | 145.0778 | CCNC [view] | Maintenance | Atmospherics | Flow inlet valve closed Leak testing | |
IN2021_T01 | 2021-06-16 22:24 [view ] | -12.0472 | 145.0747 | CCNC [view] | Maintenance | Atmospherics | Leak test successful | |
IN2021_T01 | 2021-06-16 22:26 [view ] | -12.0425 | 145.0742 | CCNC [view] | Maintenance | Atmospherics | CCNC filter check - low particle counts zero values. zero check passed | |
IN2021_T01 | 2021-06-16 22:48 [view ] | -11.9795 | 145.0673 | CCNC [view] | Maintenance | Atmospherics | DFU changed. Zero test OK. Returned to service | |
IN2021_T01 | 2021-06-16 23:42 [view ] | -11.8255 | 145.0505 | CCNC [view] | Fault | Atmospherics | air leak into the smps sample 16/6 23:26 - I just found that the air inlet tube was not connected properly. air has been sucked into the sampling system since I connected up the SMPS on 13/6 18:55. This will have affected the SMPS, and CPCs. It is possible that it will have affected the.nephelometer and CCNC. It is possible, but I think unlikely, that it also affected the ozone and greenhouse gas system, depending on the interactions in the manifold and sample lines. | |
IN2021_T01 | 2021-06-21 00:45 [view ] | -10.7378 | 135.3127 | CCNC [view] | Maintenance | Atmospherics | milliq replenished, zero readings OK | |
IN2021_V01 | 2021-02-03 19:28 [view ] | -56.8828 | 123.0275 | CCNC [view] | Maintenance | Atmospherics | milliq replenished | |
IN2021_V01 | 2021-02-04 06:09 [view ] | -57.9102 | 120.5107 | CCNC [view] | Fault | Atmospherics | Restarted. OPC error and high flow rate | |
IN2021_V01 | 2021-02-26 21:39 [view ] | -62.0593 | 65.0000 | CCNC [view] | Maintenance | Atmospherics | milliq replenished | |
IN2021_V01 | 2021-03-10 02:04 [view ] | -63.0228 | 79.8528 | CCNC [view] | Maintenance | Atmospherics | milliq replenished | |
IN2021_V02 | 2021-04-20 04:01 [view ] | -46.9518 | 142.4443 | CCNC [view] | Maintenance | Atmospherics | milliq replenished | |
IN2021_V02 | 2021-04-20 06:19 [view ] | -46.9717 | 142.3815 | CCNC [view] | Fault | Atmospherics | Serial output was not connected Serial output was not connected, preventing GORE from collecting data. The serial configuration was also screwed up, preventing the strings from having any sensible data. Trevor plugged in the serial cable, I have fixed the serial config and restarted the software. all appears to be working now. | |
IN2021_V02 | 2021-04-27 11:44 [view ] | -43.8060 | 146.9795 | CCNC [view] | Maintenance | Atmospherics | milliq replenished | |
IN2021_V03 | 2021-05-02 08:12 [view ] | -42.8863 | 147.3388 | CCNC [view] | Change | Atmospherics | CCN back to auto SS mode left sampling Lab air overnight | |
IN2021_V03 | 2021-05-02 23:21 [view ] | -42.8863 | 147.3388 | CCNC [view] | Maintenance | Atmospherics | Annual maintenance Flow check before maintenance - 497.7 ccm Zero leak check OK. 11:35 shutting down No spare DFUs in the maintenance kit. Checked DFU on the CPC and it quickly went to zero where it remained steady. Desiccant tube checked OK. Removed valve from above DFU and discovered it was in the wrong way (flow in the wrong direction compared to the DFU). Need to check. Decided to delay the OPC clean the bisque disinfecting for next time and practice and document on the CSC CCN which is about to go back to DMT anyway. Removed the capillary, sampling inlet manifolds (x2), and flow valve for cleaning in the ultrasonic. Exchanged the nafion for a new one. Checking pressure transducer against the one on the port side rack (after disconnecting from the manifold). CCN: 1015.7 hPa Barometer: 1016.4 hPa OK! Leak check - passed! Approx 0.1 mbar increase per second. ===================== Flow cal: Check before doing anything - 502.1 ccm (n=11) FlowCal tab values before doing anything: Sample flow y-int = -117.218 Sample flow Slope = 58.6627 Sheath flow y-int = -1557.34 Sheath flow slope = 689.24 Abs pressure y-int = 107 Abs pressure slope = 222.53 Set sample flow y-int and slope to 0 and 1, respectively and blocked the sheath flow path. Tried to do the sample cal and there was no flow. Checked capillary for condensation but it was OK. Checking flow directly into the top of the column, and still nothing. Suspect some issue with the nafion (as suggested in manual). Removing the nafion - I possibly kinked it when pushing it through accidentally. Removed the whole thing for inspection - compared to a new one, its lost a lot of colour, and it does indeed have a kink. Replacing with a new one. The new one was soaked in milliQ water in a clean ice-cream container for 10 minutes prior to insertion. Seems to have come good again. Flow calibration results: Sample flow y-int = -118.03 Sample flow slope = 59.102 Sheath flow y-int = -1435.37 Sheath flow slope = 646.72 Turned manual override off to verify flows. Sheath flow software read and gilibrator read within about 2 ccm (455 ccm) - OK Sample flow software read and gilibrator read within about 2 ccm (43 ccm) - OK Flow ratio 10.5 - OK | |
IN2021_V03 | 2021-05-11 05:44 [view ] | -34.4232 | 152.4793 | CCNC [view] | Outage | Atmospherics | CCN flows went bad an hour after calibration on 3 May Trying to restart the software as a remote solution, but we probably need to replace the filter. | |
IN2021_V03 | 2021-05-12 07:14 [view ] | -32.0377 | 153.2110 | CCNC [view] | Maintenance | Atmospherics | Replaced Water | |
IN2021_V03 | 2021-05-13 09:45 [view ] | -29.5258 | 154.2123 | CCNC [view] | Maintenance | Atmospherics | removed cover to identify filter | |
IN2021_V03 | 2021-05-13 11:42 [view ] | -29.4275 | 154.2725 | CCNC [view] | Stop | Atmospherics | Stopped for filter change CCNC system shutdoen for filter change. Water found in air filter line. Awaiting advise from shore. | |
IN2021_V03 | 2021-05-14 03:40 [view ] | -27.1460 | 155.3170 | CCNC [view] | Fault | Atmospherics | running again sampling through hepa filter / lab air after water condensation build up in system | |
IN2021_V03 | 2021-05-17 22:18 [view ] | -27.2223 | 154.6553 | CCNC [view] | Start | Atmospherics | dry shutdown with DAS supplied | |
IN2021_V03 | 2021-05-18 23:38 [view ] | -25.7917 | 153.6472 | CCNC [view] | Start | Atmospherics | dry startup after dry out | |
IN2021_V03 | 2021-05-19 11:36 [view ] | -25.6095 | 153.7635 | CCNC [view] | Stop | Atmospherics | dry shutdown after water in lines | |
IN2021_V03 | 2021-05-23 03:56 [view ] | -26.3267 | 153.6352 | CCNC [view] | Start | Atmospherics | Sampling air inlet after drying out | |
IN2021_V03 | 2021-05-24 01:38 [view ] | -27.1573 | 154.2027 | CCNC [view] | Change | Atmospherics | sampling dry air supply to remove moisture | |
IN2021_V04 | 2021-07-04 04:33 [view ] | -12.6257 | 112.0298 | CCNC [view] | Maintenance | Atmospherics | MilliQ replenished | |
IN2021_V04 | 2021-07-05 05:10 [view ] | -10.5735 | 107.4497 | CCNC [view] | Maintenance | Atmospherics | Adjusted sheath valve to get flow ratio closer to 10. | |
IN2021_V04 | 2021-07-17 03:35 [view ] | -11.5665 | 104.2693 | CCNC [view] | Maintenance | Atmospherics | milliq replenished | |
IN2021_V04 | 2021-07-19 14:34 [view ] | -20.8806 | 108.1875 | CCNC [view] | Outage | Atmospherics | Disconnect from inlet for leak test | |
IN2021_V04 | 2021-07-19 14:54 [view ] | -20.9432 | 108.2202 | CCNC [view] | Start | Atmospherics | Inlet reconnected after leak test | |
IN2021_V04 | 2021-07-20 07:57 [view ] | -23.7997 | 109.7230 | CCNC [view] | Stop | Atmospherics | inlet disconnected for leak test | |
IN2021_V04 | 2021-07-20 08:30 [view ] | -23.8877 | 109.7698 | CCNC [view] | Start | Atmospherics | reconnected to inlet after leak test | |
IN2021_V04 | 2021-07-21 13:34 [view ] | -28.6283 | 111.2853 | CCNC [view] | Stop | Atmospherics | Dry shutdown started | |
IN2021_V04 | 2021-07-22 04:21 [view ] | -30.6232 | 113.5875 | CCNC [view] | Stop | Atmospherics | Dry shutdown complete. PC Shutdown, power at box turned off, power at PSU turned off, inlet valve closed, sheath meterting valve closed. | |
IN2021_V04 | 2021-07-22 08:11 [view ] | -31.2187 | 113.8445 | CCNC [view] | Start | Atmospherics | Dry start up | |
IN2022_V02 | 2022-04-02 02:47 [view ] | CCN [view] | Cloud Condensation Nuclei Counter event |