Please login if you have access to particular applications.
Search for events by voyage, equipment, action or within comments.
Event count for each voyage, equipment or action is shown in ().
Found 108 records. Showing events 1 to 50
Survey | When (UTC) | Latitude | Longitude | Instrument | Identifier | Action | Log | Subject / Comments |
---|---|---|---|---|---|---|---|---|
IN2021_V04 | 2021-07-26 07:48 [view ] | -40.7068 | 132.2145 | Aerosol Lab [view] | Change | Atmospherics | Air con set to 22 degrees with fan always on (lab was getting too cold) | |
IN2018_V02 | 2018-03-09 07:00 [view ] | -46.9910 | 141.9930 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Ship exhaust sampling for TM, RV2018_V02_01SE STOP | |
IN2018_V02 | 2018-03-09 07:10 [view ] | -46.9902 | 141.9921 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Ship exhaust sampling for TM, RV2018_V02_01SEPB, procedure blank in Aerosol Lab | |
IN2018_V02 | 2018-03-09 21:43 [view ] | -46.0560 | 142.1810 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_05 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-09 22:04 [view ] | -46.0560 | 142.1810 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_06 (L1 and L2), START | |
IN2018_V02 | 2018-03-10 22:12 [view ] | -45.5230 | 142.1590 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_06 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-10 22:30 [view ] | -45.5230 | 142.1590 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_02PB (L1 and L2), 3 minutes procedure blank | |
IN2018_V02 | 2018-03-12 01:55 [view ] | -42.8864 | 147.3388 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Ship exhaust sampling for TM, RV2018_V02_02SE START | |
IN2018_V02 | 2018-03-12 02:15 [view ] | -42.8864 | 147.3388 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Ship exhaust sampling for TM, RV2018_V02_02SE STOP | |
IN2018_V02 | 2018-03-12 05:05 [view ] | -43.1180 | 147.4450 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_07 (L1 and L2), START | |
IN2018_V02 | 2018-03-12 06:53 [view ] | -43.4200 | 147.4500 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_07 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-12 07:08 [view ] | -43.4630 | 147.4390 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_08 (L1 and L2), START | |
IN2018_V02 | 2018-03-13 21:41 [view ] | -46.9950 | 142.0090 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_08 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-13 22:13 [view ] | -46.9970 | 142.0090 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_09 (L1 and L2), START | |
IN2018_V02 | 2018-03-14 02:38 [view ] | -46.9850 | 141.9960 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Ship exhaust sampling for TM, RV2018_V02_03SE START | |
IN2018_V02 | 2018-03-14 03:03 [view ] | -46.9824 | 141.9966 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Ship exhaust sampling for TM, RV2018_V02_03SE STOP | |
IN2018_V02 | 2018-03-14 21:26 [view ] | -46.9940 | 142.0010 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_09 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-14 21:40 [view ] | -46.9940 | 142.0010 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_03PB (L1 and L2), 3minutes procedure blank | |
IN2018_V02 | 2018-03-14 21:57 [view ] | -46.9940 | 142.0010 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_10 (L1 and L2), START | |
IN2018_V02 | 2018-03-16 11:25 [view ] | -46.9930 | 141.8950 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_10 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-16 11:45 [view ] | -46.9840 | 141.8920 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_11 (L1 and L2), START | |
IN2018_V02 | 2018-03-17 12:31 [view ] | -45.8710 | 141.7760 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_11 (L1 and L2), STOP | |
IN2018_V02 | 2018-03-17 12:48 [view ] | -45.9140 | 141.7740 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_12 (L1 and L2), START | |
IN2018_V02 | 2018-03-20 01:45 [view ] | -44.6950 | 143.2660 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_04PB (L1 and L2), 3minutes procedure blank | |
IN2018_V02 | 2018-03-20 01:47 [view ] | -44.6950 | 143.2660 | Aerosol Lab [view] | Air Sampling | in2018_v02 | Aerosol sampling for TM, RV2018_V02_12 (L1 and L2), STOP | |
IN2018_T01 | 2018-04-12 23:30 [view ] | -31.3683 | 154.1238 | Aerosol Lab [view] | Temperature Adjusted | in2018_t01 | Temp set to 25 | |
IN2018_V04 | 2018-09-21 18:41 [view ] | -40.1233 | 153.4418 | Aerosol Lab [view] | Maintenance | Atmospherics_in2018_v04 | Velocity measurement on manifold. Plug removed for 20 minutes. Max velocity reading: 19.3m/s | |
IN2018_V05 | 2018-10-21 16:05 [view ] | -54.9627 | 149.0070 | Aerosol Lab [view] | Observation | Atmospherics_in2018_v05 | Wrapped nafion dryers in insulation (partially) to see if it explains dewpoint cycling of sample air | |
IN2018_V05 | 2018-10-24 12:44 [view ] | -55.6572 | 150.7615 | Aerosol Lab [view] | Maintenance | Atmospherics_in2018_v05 | emptied inlet water drain bottle | |
IN2018_V06 | 2018-11-26 22:13 [view ] | -44.3050 | 147.1747 | Aerosol Lab [view] | Observation | in2018_v06_Atmospherics | lab check. all good | |
IN2018_V06 | 2018-11-28 19:59 [view ] | -44.2985 | 147.2678 | Aerosol Lab [view] | Observation | in2018_v06_Atmospherics | Lab check. All good CPC butanol should be changed tomorrow | |
IN2018_V06 | 2018-12-07 03:27 [view ] | -44.2317 | 146.1712 | Aerosol Lab [view] | Maintenance | in2018_v06_Atmospherics | Manifold catchpot emptied | |
IN2018_V06 | 2018-12-12 01:42 [view ] | -44.2390 | 147.4658 | Aerosol Lab [view] | Maintenance | in2018_v06_Atmospherics | Installed MAAP bypass MFC Flow rate set to 1LPM. Serial number 179326 | |
IN2018_V06 | 2018-12-18 18:58 [view ] | -42.9947 | 147.3830 | Aerosol Lab [view] | Stop | in2018_v06_Atmospherics | shut down for christmas port period | |
IN2019_V01 | 2019-02-17 04:50 [view ] | -66.3613 | 152.3722 | Aerosol Dry Air Supply [view] | Outage | in2019_v01_Atmospherics | main tap turned off for short period to install Tee to feed dry air to airchem lab | |
IN2019_V06 | 2019-10-28 12:34 [view ] | -13.4892 | 121.5302 | Aerosol Lab [view] | Change | in2019_v06_Atmospherics | Air conditioning vent direction changed I changed the direction of this a few days ago so that it wasn& 39;t directly blowing onto the PTRMS line, since it was causing condensation. I think this meant it was blowing directly onto the MAAP and aerosol sample lines instead, which increased the RH in those lines to 60%. I think will came in about an hour or so ago and redirected one of them down again onto the PTRMS line, which has resulted in condensation again. I have changed it back for now. Now 12:42 - I have just added a bunch of towels over the insulated PTRMS line and pointed the AC fan down. | |
IN2019_V06 | 2019-10-30 10:34 [view ] | -13.7980 | 121.9578 | Aerosol Lab [view] | in2019_v06_Atmospherics | Wrapped the PTRMS line in bubble wrap and readjusted the AC vents to the correct downward direction again | ||
IN2019_V06 | 2019-11-04 00:43 [view ] | -14.2902 | 121.4613 | Aerosol Lab [view] | in2019_v06_Atmospherics | Packing up AIRBOX O3 and NOx in aerosol lab | ||
IN2019_V06 | 2019-11-04 00:47 [view ] | -14.2902 | 121.4613 | Aerosol Lab [view] | in2019_v06_Atmospherics | Removed AIRBOX O3 exhaust line from butanol exhaust and plugged it with paper after a small butanol smell was detected in that corner | ||
IN2019_V06 | 2019-11-06 23:23 [view ] | -13.4892 | 121.5302 | Aerosol Lab [view] | Change | in2019_v06_Atmospherics | Air conditioning vent direction changed slightly I discovered that the filters sitting under the AC were soaking wet this morning. Since there are no waves, its likely it was condensation. I have changed the direction slightly so its not directly on the cartridges. Not sure why this is the first time this has happened. | |
IN2019_V06 | 2019-11-13 19:01 [view ] | -11.2115 | 133.4392 | Aerosol Lab [view] | Change | in2019_v06_Atmospherics | Insulation installed on nafions The sample line temperatures were fluctuating significantly due to the air conditioning. I have insulated the nafions as they are the largest surface. The temps are now stable/reflective of outside temp. | |
IN2019_V06 | 2019-11-20 03:43 [view ] | -12.0930 | 130.6395 | Aerosol Lab [view] | Change | in2019_v06_Atmospherics | changes to air flow I have applied some makeshift | |
IN2019_V06 | 2019-12-17 00:03 [view ] | Aerosol Lab [view] | Change | in2019_v06_Atmospherics | Lab temp reduced to 22 for port period | |||
IN2020_V01 | 2020-01-13 01:01 [view ] | -41.1913 | 104.4422 | Aerosol Lab [view] | Change | in2020_v01_Atmospherics | Changed Aerosol Lab temperature to 22 degrees Ian requested the lab temperature to be set to 22 degrees once the dew point outside is consistently below 20 degrees | |
IN2020_E01 | 2020-07-29 09:16 [view ] | -42.9727 | 147.3807 | Aerosol Lab [view] | Change | in2020_e01_Atmospherics | Aerosol lab Interface unit - additional sensor installed Rotronics probe installed to monitor labratory temp hum and dew point | |
IN2021_V01 | 2021-01-29 17:09 [view ] | -44.4872 | 145.9657 | Aerosol Lab [view] | Change | Atmospherics | AC setpoint reduced to 22 degrees | |
IN2021_V01 | 2021-01-31 02:38 [view ] | -48.5908 | 140.5403 | Aerosol Lab [view] | Change | Atmospherics | AC unit fan set to always on, temp set to 21 degrees for colder climate AC was getting to temp then automatically turning the fan off, I think this was resulting in a pocket of cooled air around the AC unit. The fan is now set to always on to ensure that air will continue circulating around the AC unit while the AC unit is not heating or cooling. | |
IN2021_V01 | 2021-03-22 18:50 [view ] | -46.1260 | 144.6073 | Aerosol Lab [view] | Change | Atmospherics | Changed AC set point to 21 degrees Lab temp was very high (29 degrees) - set point was 24 degrees and I changed it to 21 | |
IN2021_V03 | 2021-05-13 23:12 [view ] | -27.4018 | 155.1400 | Aerosol Lab [view] | Change | Atmospherics | AC temp 25C | |
IN2021_V04 | 2021-07-19 14:38 [view ] | -20.8954 | 108.1953 | Aerosol Lab [view] | Atmospherics | LICOR connected on aerosol line in place of CCN |