Survey When (UTC) LatitudeLongitude InstrumentIdentifierActionLogSubject / Comments
IN2016_E01 2016-08-19 05:21 [view ] -43.8097 150.5882 SMPS [view] Start in2016_e01 Restarted scheduler Noted that this instrument was not running despite being started at the beginning of the voyage.
IN2016_V03 2016-04-26 11:54 [view ] -43.0635 147.3946 SMPS [view] Start Atmos_in2016_v03 Sampling started Started sampling with Long TSI SMPS
IN2016_V03 2016-05-14 03:15 [view ] -57.0082 -170.0010 SMPS [view] Flow check Atmos_in2016_v03 TSI Long SMPS Disconnected from inlet. Inlet capped. Flow & zero checks. Silica replaced. Reconnected at 03:43UTC
IN2016_V03 2016-05-14 03:49 [view ] -57.0098 -170.0016 SMPS [view] Flow check Atmos_in2016_v03 GRIMM NanoSMPS checks Disconnected from inlet. Inlet tap closed. Flow check. Reconnected at 03:50UTC
IN2016_V03 2016-05-18 02:39 [view ] -50.8378 -170.0117 SMPS [view] Flow check Atmos_in2016_v03 TSI Long SMPS Disconnected and capped aerosol sampling line. Flow & zero checks. Re-connected to inlet at 02:49UTC
IN2016_V03 2016-05-18 02:54 [view ] -50.7857 -170.0090 SMPS [view] Flow check Atmos_in2016_v03 GRIMM NanoSMPS checks Disconnected aerosol sampling line and closed valve. Flow check. Reconnected at 02:55UTC
IN2016_V03 2016-05-22 01:50 [view ] -45.1760 -172.7364 SMPS [view] Flow check Atmos_in2016_v03 TSI Long SMPS Disconnected and capped aerosol sampling line. Flow check. Reconnected sampling line at 02:03
IN2016_V03 2016-05-22 02:20 [view ] -45.1750 -172.7383 SMPS [view] Flow check Atmos_in2016_v03 GRIMM NanoSMPS checks Disconnected aerosol sampling line and closed valve. Flow check. Reconnected sampling line at 02:21UTC
IN2016_V03 2016-05-23 04:35 [view ] -44.1562 -173.9371 SMPS [view] Stop Atmos_in2016_v03 TSI Long SMPS Stopped sampling to replace silica on makeup line. Restarted sampling at 4:42UTC
IN2017_T01 2017-09-29 17:46 [view ] -13.1356 147.8796 SMPS [view] Stop in2017_t01 SMPS stopped due to high RH
IN2017_T02 2017-11-14 22:08 [view ] -34.7162 115.1207 SMPS [view] maintenance in2017_t02 settings changed, schedule restarted changed D Max Scan from 350 to 1093.95 (full length scan)
IN2017_T02 2017-11-15 04:12 [view ] -35.1125 116.4495 SMPS [view] maintenance in2017_t02 attempt restart - failed keeps failing if D Max Scan is set to 1093. tried again but it failed
IN2018_C01 2018-06-02 13:45 [view ] -39.1823 146.4858 SMPS [view] Fault Atmospherics_in2018_c01 Removed due to DMA fault.
IN2018_T01 2018-04-13 03:00 [view ] -30.7582 154.1065 SMPS [view] Start in2018_t01
IN2018_V01 2018-01-25 11:25 [view ] -58.3519 139.8523 SMPS GRIMM [view] Atmospherics in2018_v01 Flow check 294 ccm
IN2018_V01 2018-01-31 00:40 [view ] -64.8106 139.8592 SMPS GRIMM [view] Atmospherics in2018_v01 Took off sampling line for zero and flow check
IN2018_V01 2018-02-11 04:59 [view ] -62.5001 132.0497 SMPS GRIMM [view] Atmospherics in2018_v01 Taken offline for zero and flow check for 2 minutes Flow 295.7 ccm Zero OK
IN2018_V01 2018-02-16 04:53 [view ] -57.9304 131.9816 SMPS GRIMM [view] Atmospherics in2018_v01 Taken offline for zero and flow check Flow 290 ccm Zero OK
IN2018_V01 2018-02-21 20:20 [view ] -42.9358 147.3883 SMPS GRIMM [view] Atmospherics in2018_v01 Final flow and zero checks Inlet flow - 292 Inlet flow (inline with manifold) - 294 Zero OK
IN2018_V06 2018-12-05 02:34 [view ] -43.8892 147.2312 SMPS [view] Outage in2018_v06_Atmospherics Software crshed on 2/12/18 Found that the software had crashed on 2/12. Software restarted
IN2018_V06 2018-12-07 03:29 [view ] -44.2318 146.1712 SMPS [view] Fault in2018_v06_Atmospherics Software crashed
IN2018_V06 2018-12-08 00:19 [view ] -44.2123 146.2067 SMPS [view] Fault in2018_v06_Atmospherics Software crashed
IN2018_V06 2018-12-09 17:03 [view ] -44.3700 147.2028 SMPS [view] Outage in2018_v06_Atmospherics downtime to install wiretap SMPS was temporarily offline to allow for installation of "wiretap" code to sniff live data
IN2018_V06 2018-12-09 18:27 [view ] -44.2985 147.0810 SMPS [view] Outage in2018_v06_Atmospherics downtime to update wiretap
IN2018_V06 2018-12-14 16:02 [view ] -44.1905 147.3198 SMPS [view] Maintenance in2018_v06_Atmospherics Butanol refill added about 1/4 bottle. Should be sufficient for the remainder of the voyage
IN2019_E01 2019-07-21 09:08 [view ] SMPS [view] Maintenance in2019_e01_Atmospherics Running overnight zero, starting at measurement 15 or 10:17am
IN2019_E01 2019-07-21 15:00 [view ] SMPS [view] Maintenance in2019_e01_Atmospherics Annual maintenance SMPS maintenance including: - Cleaning the external impactors with kimwipe and alcohol - the nozzle on the impactor (not the preimpactor) may have been installed backwards. See new procedure for proper installation. - Cleaning the impactor at the top of the column with kimwipe and alcohol. - Reapplicaiton of a thin layer of grease to all the impactors - Cleaning of the DMA and all surfaces with kimwipes and alcohol. The DMA itself was very clean, and it was just the sections around the external screws that had a bit of corrosion on them. The brass connections looked reasonable, however one side (presumably the inlet) was dirty on the inside. - Changed the excess air filter with a new one.
IN2019_E01 2019-07-22 01:41 [view ] SMPS [view] Maintenance in2019_e01_Atmospherics Overnight zero check Completed overnight zero check. Total concentrations averaged about 5e-1, with a max of 1.5e0. This is acceptable.
IN2019_E01 2019-07-22 02:18 [view ] SMPS [view] Maintenance in2019_e01_Atmospherics Flow check Gilibrator flow check - 293.1 ccm from 6 points. Only small deviation around this of approx +/- 1 ccm. Goal is 300 ccm, so this is acceptable within 5%.
IN2019_E01 2019-07-22 02:20 [view ] SMPS [view] Maintenance in2019_e01_Atmospherics SMPS operation Leaving SMPS on, measuring lab air, until the PSL cal is performed in a few days.
IN2019_E01 2019-07-27 23:34 [view ] -9.8958 135.2510 SMPS [view] Maintenance in2019_e01_Atmospherics Flow check Gilibrator flow check at inlet - 0.280 LPM
IN2019_E01 2019-07-28 00:36 [view ] -9.9207 135.3300 SMPS [view] Maintenance in2019_e01_Atmospherics butanol filled and emptied
IN2019_E01 2019-07-28 02:16 [view ] -9.9538 135.4350 SMPS [view] Fault in2019_e01_Atmospherics Condenser temperature not reaching setpoint Butanol ran out (error 40) overnight. I refiled it and the signal came back good but error 32 is persisting (temperatures not reaching setpoint). I tried restarting the software and running the warmup, but the condenser temperature is not reaching the setpoint (10oC), and only making it to 14oC. I power cycled the instrument, leaving it off for about 30 minutes, then unplugging it from mains power for about 1 minute, before restarting (without the software). Checked about 45 min later, and the condenser temperature is down to 11.8oC. Leaving it for a while longer to see if it gets down to temperature. Left another 45 min, temperature hasn& 39;t gone any further down. Took cover off to inspect plumbing, nothing suspicious, but the air conditioner is blowing directly on the instrument - maybe the heater dump for the temperature isn& 39;t able to work against the 21oC AC. I& 39;ve readjusted the AC flow direction flaps to point directly out, rather than down as they were. No change after 15 minutes. It could be related to the humidity or some dodgy butanol - I& 39;ve connected the diffusion drier to the inlet (still sampling lab air) to test the humidity effect. No change. Leaving overnight to see if the wick wetting is the issue (removed the diffusion drier).
IN2019_E01 2019-07-28 06:42 [view ] -10.1790 136.1513 SMPS [view] Fault in2019_e01_Atmospherics Power cycled the instrument to try to get condenser temp to set point This helped it get down to 11.2oC now after 45 minutes. Power cycling again to see if I can get it that little bit further!
IN2019_E01 2019-07-29 00:01 [view ] -11.1717 139.4788 SMPS [view] Fault in2019_e01_Atmospherics Condenser temperature still out of range Came in in the morning to find the condenser temperature at 15 degrees. The software has been having trouble connecting, so maybe this is a standby mode feature? I have restarted the instrument and the PC to see if I have any luck.
IN2019_E01 2019-07-29 01:27 [view ] -11.1222 139.7778 SMPS [view] Fault in2019_e01_Atmospherics Condenser temp I& 39;ve pulled the SMPS out in order to dry the wick. Disconnected the DMA to pull it out. Taken it to dry lab. Disconnected the CPC (lots of cables!) and removed it (4 screws underneath) and relocated the CPC to the fume hood. Removed the top cover of the optics, one of the tiny circuit boards blocking one of the screws for the front plate, then removed the front plate and foam, removed the inlet protecting the saturator block and then removed the wick with tweezers. The wick is a slightly yellow colour, not sure if it was originally white or what, but it may be discoloured. Leaving in the fume hood for the day. Might put in the oven overnight to drive the last bit of the water out.
IN2019_E01 2019-07-30 04:06 [view ] -9.4642 144.4663 SMPS [view] Maintenance in2019_e01_Atmospherics PSL cal at 303 +/- 6 nm started Condenser temperature at 18.2oC (set point of 10oC).
IN2019_E01 2019-07-30 04:14 [view ] -9.4860 144.4840 SMPS [view] Maintenance in2019_e01_Atmospherics PSL cal at 100 +/- 3 nm started
IN2019_E01 2019-07-30 04:17 [view ] -9.4860 144.4840 SMPS [view] Maintenance in2019_e01_Atmospherics PSL cal at 508 +/- 8 nm started
IN2019_E01 2019-07-30 04:21 [view ] -9.4860 144.4840 SMPS [view] Maintenance in2019_e01_Atmospherics PSL cal at 81 +/- 3 nm started
IN2019_E01 2019-08-01 00:26 [view ] -13.8877 146.0652 SMPS [view] Outage in2019_e01_Atmospherics Switched instrument off to packup for repair Error 32 suggests that the peltier cooler is broken and GRIMM are asking to send it back to them in Germany. Ian is going to try to fix it in Hobart before sending it back, so I& 39;m packing everything up, including the PC.
IN2019_T01 2019-04-29 01:24 [view ] -43.3642 147.4790 SMPS [view] Maintenance in2019_t01_Atmospherics Butanol refill
IN2019_V01 2019-01-30 04:00 [view ] -64.7083 138.5850 SMPS [view] Maintenance in2019_v01_Atmospherics butanol fill
IN2019_V01 2019-02-02 18:14 [view ] -65.8125 144.3650 SMPS [view] Maintenance in2019_v01_Atmospherics Topped up butinol
IN2019_V01 2019-02-04 19:01 [view ] -65.7862 143.9258 SMPS [view] Maintenance in2019_v01_Atmospherics Butanol Refill
IN2019_V01 2019-02-08 20:06 [view ] -65.8650 146.9652 SMPS [view] Maintenance in2019_v01_Atmospherics Butanol Refill
IN2019_V01 2019-02-17 19:33 [view ] -65.9437 148.2963 SMPS [view] Maintenance in2019_v01_Atmospherics catchpot drained
IN2019_V01 2019-02-23 17:45 [view ] -65.7455 147.1073 SMPS [view] Maintenance in2019_v01_Atmospherics Butinol Refill and Cear Waste
IN2019_V01 2019-03-02 16:42 [view ] -48.2683 148.0028 SMPS [view] Maintenance in2019_v01_Atmospherics Butinol Refill and Cear Waste
IN2019_V02 2019-03-26 18:00 [view ] -46.8880 142.1828 SMPS [view] Observation in2019_v02_Atmospherics SMPS showing minute readings
IN2019_V03 2019-05-15 11:49 [view ] -34.7048 113.3088 SMPS [view] Maintenance in2019_v03_Atmospherics butanol fill
IN2019_V03 2019-05-29 00:29 [view ] -21.5005 110.0003 SMPS [view] Maintenance in2019_v03_Atmospherics Butanol Refill
IN2019_V03 2019-06-07 20:53 [view ] -16.8372 111.3282 SMPS [view] Maintenance in2019_v03_Atmospherics Butanol Refill
IN2019_V03 2019-06-12 08:18 [view ] -28.4538 113.4797 SMPS [view] Stop in2019_v03_Atmospherics Shut down for dry dock
IN2019_V06 2019-10-23 01:16 [view ] -14.3740 121.2547 SMPS [view] AIRBOX_in2019_v06 3782 Emtied drain bottle Filled supply bottle.
IN2019_V06 2019-10-23 03:01 [view ] -14.3708 121.2512 SMPS [view] Maintenance AIRBOX_in2019_v06 Restarting Restarting AIM
IN2019_V06 2019-10-23 03:06 [view ] -14.3633 121.2428 SMPS [view] Start AIRBOX_in2019_v06 Restarting Starting a new file: 20191023.s80
IN2019_V06 2019-10-24 04:50 [view ] -14.3385 121.2898 SMPS [view] Fault AIRBOX_in2019_v06 leak Branka was pulling NAIS tubes off and disconnected something. Stopped sampling
IN2019_V06 2019-10-24 05:22 [view ] -14.2655 121.2908 SMPS [view] Start AIRBOX_in2019_v06 Restarted after reconnecting
IN2019_V06 2019-10-25 00:54 [view ] -14.2702 121.2127 SMPS [view] Maintenance AIRBOX_in2019_v06 Starting new file name 20191025.s80
IN2019_V06 2019-10-25 06:59 [view ] -14.2758 121.2368 SMPS [view] Restart AIRBOX_in2019_v06 A vacuum line fell of and the SMPS stoped couting - repaired and restarted
IN2019_V06 2019-10-26 01:35 [view ] -14.1797 121.2193 SMPS [view] Fault AIRBOX_in2019_v06 AIM stopped scanning at 286 AIM stoped also for the VH-TDMA at the same time. Restarting SMPS
IN2019_V06 2019-10-26 10:37 [view ] -14.0427 122.2243 SMPS [view] Maintenance AIRBOX_in2019_v06 Changed file name
IN2019_V06 2019-10-26 11:28 [view ] -13.9903 122.1742 SMPS [view] AIRBOX_in2019_v06 Counts gone down almost half
IN2019_V06 2019-10-26 11:49 [view ] -13.9767 122.1600 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks STOPPED AFTER FROM 156
IN2019_V06 2019-10-27 00:39 [view ] -13.4555 121.5483 SMPS [view] Start AIRBOX_in2019_v06 Restarting AIM new file 20191027.s80
IN2019_V06 2019-10-28 04:59 [view ] -13.4900 121.5302 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks Flows OK aerosol 0.27lpm, changed filename 20191028.s80
IN2019_V06 2019-10-28 23:44 [view ] -13.4888 121.5292 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks All OK, see excell file
IN2019_V06 2019-10-29 00:05 [view ] -13.4883 121.5282 SMPS [view] AIRBOX_in2019_v06 drsaining CPC Restarted both labview and AIM. Draining 3772 on the H-side and put it on water removal
IN2019_V06 2019-10-29 23:14 [view ] -13.7980 121.9582 SMPS [view] Maintenance AIRBOX_in2019_v06 Daiy checks
IN2019_V06 2019-10-30 23:09 [view ] -13.7982 121.9575 SMPS [view] Maintenance AIRBOX_in2019_v06 File change in AIM
IN2019_V06 2019-10-30 23:35 [view ] -13.7983 121.9583 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
IN2019_V06 2019-10-31 23:28 [view ] -13.4993 121.6148 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks
IN2019_V06 2019-11-01 02:18 [view ] -13.6453 121.4902 SMPS [view] Observation AIRBOX_in2019_v06 Flow changed after adding CPC Had to adjust flow
IN2019_V06 2019-11-01 23:07 [view ] -14.3567 121.3950 SMPS [view] Change AIRBOX_in2019_v06 Instaling an impactor
IN2019_V06 2019-11-01 23:53 [view ] -14.2748 121.4257 SMPS [view] Start AIRBOX_in2019_v06 Restarted with impactor
IN2019_V06 2019-11-03 09:14 [view ] -14.2013 121.3422 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change All same as yesterday - see excell file
IN2019_V06 2019-11-04 00:01 [view ] -14.2908 121.4620 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow cheks and file name change
IN2019_V06 2019-11-05 00:36 [view ] -14.2433 121.9592 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-06 23:29 [view ] -13.7973 121.9577 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
IN2019_V06 2019-11-08 00:20 [view ] -13.8775 121.7593 SMPS [view] AIRBOX_in2019_v06 Changed file name
IN2019_V06 2019-11-08 22:55 [view ] -13.2897 124.0895 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-08 23:11 [view ] -13.2822 124.1465 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
IN2019_V06 2019-11-09 23:56 [view ] -12.4290 129.5855 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-10 00:01 [view ] -12.4262 129.6048 SMPS [view] Start AIRBOX_in2019_v06 restarted after daily checks
IN2019_V06 2019-11-10 06:14 [view ] -12.3088 130.6337 SMPS [view] Fault AIRBOX_in2019_v06 Placed dry air on Nafion CPC shows large counts after I placed dry air on nafion to blow
IN2019_V06 2019-11-10 06:24 [view ] -12.3122 130.6435 SMPS [view] Start AIRBOX_in2019_v06 Restarted
IN2019_V06 2019-11-10 22:36 [view ] -12.4723 130.8455 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change All ok
IN2019_V06 2019-11-11 23:05 [view ] -10.8468 130.1158 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily checks and file name change
IN2019_V06 2019-11-13 22:30 [view ] -11.2097 133.4368 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily checks and file name change
IN2019_V06 2019-11-14 00:47 [view ] -11.2068 133.4307 SMPS [view] Maintenance AIRBOX_in2019_v06 Orifice blocked (fixed) Poly flow was 0.21, adjusted sheath flow knob until 0.31. This lowered sheath flow to 1.66 (2.42 on classifier). After attempting to correct this (with no success) we found the critical orifice was blocked. We cleaned it and found sheath flow had risen to 2.9. Adjusted excess and sheath flows until all were normal again
IN2019_V06 2019-11-15 23:45 [view ] -11.2062 133.4440 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-16 22:57 [view ] -11.2075 133.4355 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-18 22:48 [view ] -12.1645 130.8462 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-19 22:58 [view ] -12.0968 130.6398 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-21 22:48 [view ] -12.3205 130.3985 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-22 22:34 [view ] -12.3100 130.4010 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-24 22:51 [view ] -12.2932 130.3867 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-25 22:21 [view ] -12.3098 130.4128 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-26 23:04 [view ] -10.8298 132.1785 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-29 22:37 [view ] -12.3107 130.4113 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-11-30 23:12 [view ] -12.3138 130.4068 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-03 21:59 [view ] -12.3117 130.4120 SMPS [view] Fault AIRBOX_in2019_v06 Failed to set scan time Checked SMPS distrbution for daily checks. Had the error "Failed to set scan time: not sampling". Unsure of how long it had this error/how long there was no sampling
IN2019_V06 2019-12-07 22:26 [view ] -12.3148 130.4270 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-08 22:53 [view ] -12.3070 130.4308 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-09 22:35 [view ] -12.6177 130.1193 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-10 22:40 [view ] -12.3037 130.4232 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-11 22:29 [view ] SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-13 23:21 [view ] -12.3087 130.4348 SMPS [view] Maintenance AIRBOX_in2019_v06 Daily flow check and file name change
IN2019_V06 2019-12-14 09:43 [view ] -12.3115 130.4245 SMPS [view] Stop AIRBOX_in2019_v06 End of sampling shutdown
IN2019_V07 2019-04-13 23:25 [view ] -39.2332 146.6352 SMPS [view] Maintenance Atmospherics_in2019_v07 Empty butonol, fill butonol reservoir
IN2019_V07 2019-04-13 23:25 [view ] -39.2332 146.6352 SMPS [view] Maintenance in2019_v07_Atmospherics Empty butonol, fill butonol reservoir
IN2020_E01 2020-08-03 13:38 [view ] -43.1653 148.1888 SMPS [view] Maintenance in2020_e01_Atmospherics Butanol filled and emptied
IN2020_V06 2020-10-14 14:42 [view ] -54.3185 159.1818 SMPS [view] Fault in2020_v06_Atmospherics SMPS software frozen. SMPS software found to be frozen and no data being produced for the last few days. Tried to restart but software wouldn& 39;t behave. Awaiting advice from Aspendale.
IN2020_V06 2020-10-15 00:00 [view ] -54.6195 158.9335 SMPS [view] Start in2020_v06_Atmospherics Cycled power and restarted data acquisition.
IN2020_V06 2020-10-21 02:51 [view ] -55.1440 157.5807 SMPS [view] Maintenance in2020_v06_Atmospherics Topped up butanol
IN2020_V06 2020-11-02 05:26 [view ] -44.2395 149.4075 SMPS [view] Maintenance in2020_v06_Atmospherics Butanol filled/drained.
IN2020_V08 2021-01-12 07:57 [view ] -51.4925 144.2710 SMPS [view] Maintenance Atmospherics_in2020_v08 Butanol refill only did a half top up last time, so finishing it up now
IN2021_T01 2021-06-13 18:55 [view ] -19.0912 149.9110 SMPS [view] Start Atmospherics connected to inlet and switched on
IN2021_T01 2021-06-13 18:55 [view ] -19.0912 149.9112 SMPS [view] Fault Atmospherics not connected properly - air leak ino aerosol systems 16/6 23:26 - I just found that the air inlet tube was not connected properly. air has been sucked into the sampling system since I connected up the SMPS on 13/6 18:55. This will have affected the SMPS, and CPCs. It is possible that it will have affected the.nephelometer and CCNC. It is possible, but I think unlikely, that it also affected the ozone and greenhouse gas system, depending on the interactions in the manifold and sample lines.
IN2021_T01 2021-06-16 23:24 [view ] -11.8753 145.0560 SMPS [view] Maintenance Atmospherics Flow test Flow test with Gilibrtor :(2x average of 5 samples, cc/min) without impactors : 284, 292 with impactors: 275, 275
IN2021_T01 2021-06-21 07:46 [view ] -10.7568 134.1223 SMPS [view] Maintenance Atmospherics condensate drain
IN2021_V01 2021-02-03 18:51 [view ] -56.8175 123.1698 SMPS [view] Outage Atmospherics SMPS power cable shook loose in rough weather I am securing the power cable better and restarting the SMPS
IN2021_V01 2021-02-03 19:29 [view ] -56.8833 123.0263 SMPS [view] Maintenance Atmospherics Butanol replenished
IN2021_V01 2021-02-03 20:13 [view ] -56.9637 122.8575 SMPS [view] Start Atmospherics Starting SMPS after power cable became disconnected
IN2021_V01 2021-02-13 05:29 [view ] -65.5230 55.0532 SMPS [view] Outage Atmospherics SMPS was unexpectedly in standby mode
IN2021_V01 2021-02-13 05:30 [view ] -65.5232 55.0530 SMPS [view] Stop Atmospherics Turned off SMPS for impactor clean (inlet valve closed)
IN2021_V01 2021-02-13 08:15 [view ] -65.5218 55.0545 SMPS [view] Start Atmospherics
IN2021_V01 2021-02-18 07:13 [view ] -63.7127 60.0000 SMPS [view] Maintenance Atmospherics butanol replenished
IN2021_V01 2021-03-05 16:36 [view ] -67.3302 74.7548 SMPS [view] Start Atmospherics Re-Started SMPS - No Data coming thorugh Software be-boot
IN2021_V01 2021-03-05 17:25 [view ] -67.3040 74.9740 SMPS [view] Start Atmospherics Re-Started SMPS The SMPS instrument was in standby as displayed by the LCD display. Re-started the instrument from fron panel this time not just a software reboot. Graph data seems to be populating now
IN2021_V01 2021-03-19 03:19 [view ] -57.0007 128.5167 SMPS [view] Start Atmospherics Starting SMPS after fault The SMPS stopped working (see attached screenshot)
IN2021_V02 2021-04-20 04:37 [view ] -46.9567 142.4297 SMPS [view] Maintenance Atmospherics Butanol replenished
IN2021_V03 2021-05-02 01:10 [view ] -42.8863 147.3388 SMPS [view] Maintenance Atmospherics Flow check issues Flow check after maintenance with gilibrator. 177 ccm. Removed impactors and flow increased to 277. Checked directly on CPC and it was around the same. Tried just having the preimpactor installed - 244 ccm Tried just having the impactor installed - 159 ccm. Swapped the critical orifices into the other housing and the low flow followed the critical orifice. So the issue is the impactor& 39;s critical orifice (1 x 0.4 mm). This is the one that had its o-ring replaced. Swapping o-rings to confirm the o-ring is the issue or not. Impactor with good o-ring still shows a low flow (160 ccm), so the issue is isolated to the actual orifice, not the o-ring. Since both impactors are still showing some flow reduction, I& 39;m cleaning them again in the ultrasonic bath. Cleaning out the ultrasonic bath properly (rinsing, wiping out with kimwipes), then using 1% triton X solution (in tap water) filled up with milliQ then run on delicate setting at 40oC for 10 minutes.
IN2021_V03 2021-05-13 07:30 [view ] -29.6372 154.1477 SMPS [view] Stop Atmospherics SMPS shutdown following advice from shore.
IN2021_V03 2021-05-14 03:40 [view ] -27.1460 155.3170 SMPS [view] Start Atmospherics started
IN2021_V03 2021-05-14 05:15 [view ] -27.1535 155.2347 SMPS [view] Stop Atmospherics Shutdown following advise from shore
IN2021_V04 2021-06-28 05:34 [view ] -12.4718 130.8468 SMPS [view] Start Atmospherics
IN2021_V04 2021-07-05 13:23 [view ] -10.6258 105.8607 SMPS [view] Maintenance Atmospherics Butanol supply filled - butanol condensate emptied