Subject: EM122 will not start pinging, failed BIST tests, troubleshooting
Event Identifier:
When: 2015-12-10 23:57:00 UTC      [entered into Elog as 2015-12-10 23:57:00]
Position:
Latitude: -35.179     Longitude: 130.6997      [entered into Elog as 35°10.74'S, 130°41.98'E]

Distance from event position with respect to underway position is 0.015 km

Equipment: EM122      Linked to equipment register: Kongsberg/Simrad EM122 12kHz multibeam echo sounder [view]
Action: Crash
Line:0153
Logfile:151210a.log
ElogName:GSM_in2015_c02
Comments:

BIST tests failed. Restarted both PC and computer. BISTS passesd but still will not ping. Ran extended telnet BIST. Failed Preamplifier tests (51 and 53). TUrned off SBP, EM122 PC and transducer and then turned off preamplified. Turned back on and booted EM122 back up. Re-ran preamplifier BISTS. Still failed. Start pinging- shows pings being fired in Ksync but does not show pings in SIS. Telnet shows "No attitude" messages. Possibly a problem with the pre-amplifier unit so the pings are being sent but not properly recieved.

Logged by:      [entered into Elog as Amy Nau]