Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-11 23:01 to 2016-07-11 23:29 UTC
Where: 39° 01.4' S 149° 54.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
26 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 8.4 | 242.96 | 35.569 | 4.19 | 15.96 | 0.35 | 0.05 | 0.16 | 1.95 |
30 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 9 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 9.1 | < 0.02 | < 0.02 | < 0.02 | 15.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 25.2 | < 0.02 | < 0.02 | 4.21 | 15.97 | 0.35 | 0.06 | 0.16 | 1.92 |
22 | 51 | < 0.02 | < 0.02 | 4.21 | 15.97 | 0.35 | 0.03 | 0.16 | 1.92 |
21 | 75.5 | < 0.02 | < 0.02 | 4.24 | 15.96 | 0.35 | 0.04 | 0.16 | 1.92 |
20 | 100.8 | < 0.02 | < 0.02 | 4.38 | 15.92 | 0.36 | 0.04 | 0.16 | 1.93 |
19 | 130.1 | < 0.02 | < 0.02 | < 0.02 | 15.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 130.1 | < 0.02 | < 0.02 | < 0.02 | 15.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 130.1 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 130.1 | < 0.02 | < 0.02 | < 0.02 | 15.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 130.2 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 130.2 | < 0.02 | < 0.02 | < 0.02 | 15.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 130.2 | < 0.02 | < 0.02 | < 0.02 | 15.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 130.3 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 130.3 | < 0.02 | < 0.02 | < 0.02 | 15.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 130.3 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 130.4 | 235.45 | 35.514 | 5.27 | 15.62 | 0.41 | 0.04 | 0.12 | 2.15 |
7 | 161.4 | < 0.02 | < 0.02 | < 0.02 | 14.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 161.4 | < 0.02 | < 0.02 | < 0.02 | 14.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 161.4 | < 0.02 | < 0.02 | < 0.02 | 14.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 161.4 | < 0.02 | < 0.02 | < 0.02 | 14.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 161.4 | 220.63 | 35.325 | 8.15 | 14.31 | 0.60 | 0.06 | < 0.02 | 2.83 |
5 | 161.5 | < 0.02 | < 0.02 | < 0.02 | 14.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 200 | < 0.02 | < 0.02 | 12.21 | 13.16 | 0.84 | 0.10 | < 0.02 | 4.35 |
1 | 250.6 | 203.97 | 35.080 | 13.64 | 12.37 | 0.92 | 0.10 | < 0.02 | 5.00 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |