Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-09 19:36 to 2016-07-09 20:42 UTC
Where: 31° 14.5' S 155° 23.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 21.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 21.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 21.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 6.9 | < 0.02 | < 0.02 | 1.35 | 21.29 | 0.16 | 0.17 | 0.20 | 0.87 |
35 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 25.4 | < 0.02 | < 0.02 | 1.35 | 21.30 | 0.16 | 0.13 | 0.20 | 0.87 |
22 | 50.4 | 213.97 | 35.737 | 1.34 | 21.31 | 0.16 | 0.12 | 0.21 | 0.86 |
21 | 75.2 | < 0.02 | < 0.02 | 1.34 | 21.32 | 0.16 | 0.09 | 0.21 | 0.84 |
20 | 100.4 | < 0.02 | < 0.02 | 1.35 | 21.33 | 0.16 | 0.12 | 0.21 | 0.87 |
9 | 174.4 | 213.48 | 35.733 | 1.39 | 21.34 | 0.16 | 0.12 | 0.20 | 0.88 |
13 | 174.5 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 174.5 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 174.5 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 174.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 174.7 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 225.1 | < 0.02 | < 0.02 | 2.14 | 20.64 | 0.19 | 0.07 | 0.02 | 0.86 |
8 | 225.1 | < 0.02 | < 0.02 | < 0.02 | 20.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 225.2 | < 0.02 | < 0.02 | < 0.02 | 20.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 225.3 | < 0.02 | < 0.02 | < 0.02 | 20.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 400.7 | < 0.02 | < 0.02 | 3.97 | 19.11 | 0.31 | 0.09 | < 0.02 | 1.33 |
3 | 600.2 | 200.48 | 35.677 | 12.93 | 13.35 | 0.88 | 0.11 | < 0.02 | 4.64 |
2 | 800.6 | < 0.02 | < 0.02 | 21.30 | 9.08 | 1.39 | 0.10 | < 0.02 | 10.05 |
1 | 992 | 201.96 | 34.486 | 26.16 | 6.95 | 1.72 | 0.13 | < 0.02 | 19.64 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |