Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-08 23:02 to 2016-07-08 23:32 UTC
Where: 28° 04.0' S 155° 59.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Oxygen (µM)  | 
 
Salinity (psu)  | 
 
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Nitrite (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|---|---|
| 32 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 25 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 28 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 29 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 30 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 27 | 6 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 31 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 24 | 6.1 | 217.59 | 35.739 | 0.17 | 22.24 | 0.08 | 0.20 | 0.04 | 0.69 | 
| 26 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 34 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 33 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 23 | 9.8 | < 0.02 | < 0.02 | 0.17 | 22.24 | 0.08 | 0.17 | 0.04 | 0.64 | 
| 22 | 24.8 | < 0.02 | < 0.02 | 0.16 | 22.24 | 0.08 | 0.18 | 0.04 | 0.63 | 
| 21 | 51 | < 0.02 | < 0.02 | 0.19 | 22.24 | 0.09 | 0.21 | 0.04 | 0.63 | 
| 20 | 74.8 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 18 | 74.9 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 10 | 75 | 217.10 | 35.752 | 0.24 | 22.17 | 0.09 | 0.19 | 0.07 | 0.59 | 
| 17 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 15 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 14 | 75.3 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 12 | 75.4 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 11 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 13 | 75.5 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 16 | 75.8 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 19 | 76.3 | < 0.02 | < 0.02 | < 0.02 | 22.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 9 | 100.5 | < 0.02 | < 0.02 | 0.25 | 22.16 | 0.10 | 0.18 | 0.08 | 0.60 | 
| 4 | 176.1 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 6 | 176.4 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 8 | 176.5 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 5 | 176.5 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 7 | 177 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 3 | 177.5 | 189.09 | 35.712 | 3.56 | 20.74 | 0.32 | 0.09 | 0.03 | 0.91 | 
| 2 | 201 | < 0.02 | < 0.02 | 3.66 | 20.08 | 0.31 | 0.12 | 0.03 | 0.88 | 
| 1 | 251.8 | 187.40 | 35.627 | 5.91 | 19.03 | 0.43 | 0.12 | 0.03 | 1.34 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) | 
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) | 
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) | 
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Seabird SBE-32 | Seabird | SBE-32 | 263 | |
| Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) | 
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) | 
| Transmissometer | SeaTech | Transmittance (%) |