Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-08 06:45 to 2016-07-08 07:48 UTC
Where: 25° 49.1' S 156° 01.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
30 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 23.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 23.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 6 | < 0.02 | < 0.02 | < 0.02 | 23.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6.5 | < 0.02 | < 0.02 | 0.06 | 23.57 | 0.10 | 0.38 | 0.03 | 0.80 |
29 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 23.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 24.9 | < 0.02 | < 0.02 | < 0.02 | 23.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 25.3 | < 0.02 | < 0.02 | 0.05 | 23.58 | 0.09 | 0.52 | 0.03 | 0.80 |
25 | 25.6 | < 0.02 | < 0.02 | < 0.02 | 23.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 49.6 | < 0.02 | < 0.02 | 0.05 | 23.59 | 0.09 | 0.45 | 0.03 | 0.79 |
22 | 49.7 | < 0.02 | < 0.02 | < 0.02 | 23.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 60.8 | 209.06 | 35.630 | 0.04 | 23.56 | 0.09 | 0.41 | 0.03 | 0.75 |
20 | 60.9 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 60.9 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 61 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 100.7 | < 0.02 | < 0.02 | 0.04 | 23.53 | 0.09 | 0.42 | 0.03 | 0.79 |
16 | 101 | < 0.02 | < 0.02 | < 0.02 | 23.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 160.8 | < 0.02 | < 0.02 | < 0.02 | 22.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 160.9 | < 0.02 | < 0.02 | < 0.02 | 22.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 160.9 | < 0.02 | < 0.02 | < 0.02 | 22.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 160.9 | < 0.02 | < 0.02 | 4.16 | 22.03 | 0.38 | 0.49 | 0.03 | 1.40 |
9 | 250.9 | < 0.02 | < 0.02 | < 0.02 | 19.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 251.2 | < 0.02 | < 0.02 | < 0.02 | 19.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 402.5 | < 0.02 | < 0.02 | < 0.02 | 14.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 402.7 | 183.07 | 35.251 | 10.92 | 14.95 | 0.81 | 0.31 | < 0.02 | 4.17 |
5 | 601.9 | < 0.02 | < 0.02 | 19.84 | 9.50 | 1.37 | 0.35 | < 0.02 | 9.30 |
6 | 602 | < 0.02 | < 0.02 | < 0.02 | 9.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 800.9 | < 0.02 | < 0.02 | < 0.02 | 6.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 800.9 | < 0.02 | 34.452 | 26.21 | 6.65 | 1.80 | 0.48 | < 0.02 | 21.80 |
2 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 5.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1000.8 | < 0.02 | 34.449 | 30.22 | 5.08 | 2.08 | 0.43 | < 0.02 | 42.59 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |