Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-06 23:04 to 2016-07-06 23:32 UTC
Where: 21° 57.8' S 159° 38.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Oxygen (µM)  | 
 
Salinity (psu)  | 
 
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Nitrite (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|---|---|
| 30 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 25 | 5.2 | 214.55 | 35.717 | 0.02 | 23.61 | 0.07 | 0.05 | < 0.02 | 0.84 | 
| 31 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 32 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 29 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 27 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 26 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 28 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 33 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 24 | 9.8 | < 0.02 | < 0.02 | 0.03 | 23.61 | 0.07 | 0.06 | < 0.02 | 0.89 | 
| 23 | 23.9 | < 0.02 | < 0.02 | 0.03 | 23.58 | 0.07 | 0.06 | < 0.02 | 0.91 | 
| 14 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 21 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 18 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 22 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 17 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 23.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 13 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 19 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 16 | 50.9 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 20 | 50.9 | < 0.02 | < 0.02 | < 0.02 | 23.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 15 | 50.9 | < 0.02 | < 0.02 | < 0.02 | 23.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 12 | 50.9 | 204.46 | 35.727 | 0.75 | 23.13 | 0.14 | 0.07 | 0.08 | 0.98 | 
| 11 | 75.4 | < 0.02 | < 0.02 | 0.80 | 22.60 | 0.14 | 0.16 | 0.08 | 1.01 | 
| 7 | 99.5 | < 0.02 | < 0.02 | < 0.02 | 21.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 10 | 99.5 | < 0.02 | < 0.02 | < 0.02 | 21.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 9 | 99.6 | < 0.02 | < 0.02 | < 0.02 | 21.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 5 | 99.6 | 195.21 | 35.725 | 1.97 | 21.58 | 0.23 | 0.05 | 0.04 | 1.14 | 
| 8 | 99.6 | < 0.02 | < 0.02 | < 0.02 | 21.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 6 | 99.6 | < 0.02 | < 0.02 | < 0.02 | 21.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 4 | 150.3 | < 0.02 | < 0.02 | 3.45 | 20.81 | 0.31 | 0.04 | 0.02 | 1.29 | 
| 3 | 200.1 | < 0.02 | < 0.02 | 3.34 | 19.76 | 0.29 | 0.04 | < 0.02 | 1.24 | 
| 2 | 250 | 200.08 | 35.665 | 3.83 | 18.82 | 0.32 | 0.08 | < 0.02 | 1.41 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) | 
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) | 
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) | 
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Seabird SBE-32 | Seabird | SBE-32 | 263 | |
| Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) | 
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) | 
| Transmissometer | SeaTech | Transmittance (%) |