Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-05 22:00 to 2016-07-05 22:32 UTC
Where: 20° 00.4' S 160° 53.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
30 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 25.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 4 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 4.3 | 210.26 | 35.627 | < 0.02 | 25.06 | 0.04 | 0.15 | 0.03 | 0.86 |
22 | 9.6 | < 0.02 | < 0.02 | < 0.02 | 25.07 | 0.05 | 0.16 | 0.03 | 0.89 |
21 | 23.8 | < 0.02 | < 0.02 | < 0.02 | 25.07 | 0.05 | 0.15 | 0.03 | 0.88 |
20 | 49.8 | < 0.02 | < 0.02 | < 0.02 | 25.08 | 0.05 | 0.13 | 0.03 | 0.86 |
19 | 74.5 | < 0.02 | < 0.02 | < 0.02 | 25.08 | 0.05 | 0.13 | 0.03 | 0.88 |
18 | 99.7 | < 0.02 | < 0.02 | < 0.02 | 25.08 | 0.05 | 0.13 | 0.04 | 0.89 |
14 | 125.4 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 125.4 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 125.5 | < 0.02 | < 0.02 | < 0.02 | 23.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 125.5 | < 0.02 | < 0.02 | < 0.02 | 23.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 125.5 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 125.5 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 125.5 | 200.53 | 35.665 | 0.92 | 23.54 | 0.16 | 0.14 | 0.21 | 0.97 |
15 | 125.5 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 125.6 | < 0.02 | < 0.02 | < 0.02 | 23.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 175 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 175 | 189.01 | 35.704 | 3.52 | 20.74 | 0.31 | 0.17 | 0.05 | 1.33 |
6 | 175 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 175.1 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 175.1 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 175.1 | < 0.02 | < 0.02 | < 0.02 | 20.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 199.6 | < 0.02 | < 0.02 | 3.99 | 20.04 | 0.34 | 0.16 | 0.05 | 1.43 |
1 | 253.3 | 191.73 | 35.640 | 4.66 | 19.09 | 0.38 | 0.15 | 0.06 | 1.58 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |