Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-04 22:11 to 2016-07-04 22:40 UTC
Where: 20° 19.7' S 161° 36.3' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
25 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 6.4 | 210.58 | 35.630 | < 0.02 | 24.84 | 0.05 | 0.06 | < 0.02 | 0.88 |
27 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 7 | < 0.02 | < 0.02 | < 0.02 | 24.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 9.9 | < 0.02 | < 0.02 | < 0.02 | 24.84 | 0.05 | 0.05 | < 0.02 | 0.90 |
21 | 24.3 | < 0.02 | < 0.02 | < 0.02 | 24.84 | 0.05 | 0.06 | < 0.02 | 0.93 |
20 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 24.84 | 0.05 | 0.03 | < 0.02 | 0.89 |
15 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 80.5 | 207.41 | 35.682 | 0.13 | 24.02 | 0.10 | 0.05 | 0.08 | 0.91 |
13 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 24.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 24.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 22.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 100.2 | 192.89 | 35.688 | 1.81 | 22.81 | 0.23 | 0.07 | 0.05 | 1.11 |
8 | 100.2 | < 0.02 | < 0.02 | < 0.02 | 22.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 100.2 | < 0.02 | < 0.02 | < 0.02 | 22.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 100.2 | < 0.02 | < 0.02 | < 0.02 | 22.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 22.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 149.6 | < 0.02 | < 0.02 | 3.05 | 21.40 | 0.29 | 0.05 | 0.02 | 1.20 |
2 | 200 | < 0.02 | < 0.02 | 3.86 | 20.22 | 0.33 | 0.04 | < 0.02 | 1.32 |
1 | 250.6 | 187.62 | 35.604 | 5.53 | 18.74 | 0.44 | 0.05 | < 0.02 | 1.81 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |