Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-03 22:41 to 2016-07-03 23:09 UTC
Where: 21° 13.2' S 163° 10.1' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
24 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 7.2 | 214.60 | 35.743 | < 0.02 | 24.32 | 0.04 | 0.05 | < 0.02 | 0.92 |
28 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 24.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 24.31 | 0.05 | 0.18 | < 0.02 | 0.94 |
21 | 25.5 | < 0.02 | < 0.02 | < 0.02 | 24.31 | 0.05 | 0.02 | < 0.02 | 0.92 |
20 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 24.31 | 0.05 | < 0.02 | < 0.02 | 0.92 |
19 | 73.6 | < 0.02 | < 0.02 | < 0.02 | 24.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 22.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 22.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 100.4 | 202.89 | 35.705 | 0.65 | 22.52 | 0.17 | 0.05 | 0.17 | 1.06 |
16 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 22.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 22.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 100.6 | < 0.02 | < 0.02 | < 0.02 | 22.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 100.6 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 150.3 | < 0.02 | < 0.02 | < 0.02 | 21.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 150.3 | < 0.02 | < 0.02 | < 0.02 | 21.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 150.4 | < 0.02 | < 0.02 | < 0.02 | 21.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 150.4 | 191.37 | 35.729 | 2.73 | 21.25 | 0.27 | 0.03 | 0.02 | 1.20 |
7 | 150.6 | < 0.02 | < 0.02 | < 0.02 | 21.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 150.6 | < 0.02 | < 0.02 | < 0.02 | 21.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 200.1 | < 0.02 | < 0.02 | 3.38 | 19.99 | 0.31 | 0.05 | < 0.02 | 1.33 |
1 | 250.7 | 197.45 | 35.656 | 4.11 | 18.87 | 0.36 | 0.04 | < 0.02 | 1.55 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |