Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 20 - SN 0552,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-07-02 22:41 to 2016-07-02 23:11 UTC
Where: 23° 08.2' S 167° 04.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
31 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 6 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 6 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 6 | 215.31 | 35.669 | 0.12 | 23.10 | 0.07 | 0.11 | 0.02 | 0.83 |
22 | 10.7 | < 0.02 | < 0.02 | 0.13 | 23.10 | 0.08 | 0.09 | 0.03 | 0.85 |
14 | 24.1 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 24.1 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 24.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 24.2 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 24.3 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 24.3 | 215.36 | 35.668 | 0.13 | 23.10 | 0.07 | 0.09 | 0.02 | 0.83 |
21 | 24.4 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 23.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 50.4 | < 0.02 | < 0.02 | 0.16 | 23.12 | 0.07 | 0.09 | 0.02 | 0.84 |
10 | 75.4 | < 0.02 | < 0.02 | 0.46 | 22.92 | 0.09 | 0.08 | 0.04 | 0.84 |
4 | 100.4 | 200.13 | 35.687 | 2.85 | 20.62 | 0.25 | < 0.02 | 0.06 | 1.12 |
7 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 20.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 20.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 20.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 20.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 20.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 150.3 | < 0.02 | < 0.02 | 3.39 | 20.04 | 0.29 | < 0.02 | 0.03 | 1.22 |
2 | 200 | < 0.02 | < 0.02 | 4.41 | 18.91 | 0.36 | < 0.02 | < 0.02 | 1.37 |
1 | 250.3 | 196.15 | 35.541 | 6.10 | 17.52 | 0.47 | 0.02 | < 0.02 | 1.89 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |