Deployment Details
Survey: - IN2017_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 2312,Fluorometer-CTD20-Chelsea-11-8206-01,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751
When: 2017-02-20 10:36 to 2017-02-20 11:28 UTC
Where: 65° 32.3' S 120° 24.4' E
Maximum Depth (m): 941.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1213 | 2.9 | 354.70 | 32.927 | 27.19 | -1.51 | 1.90 | 1.65 | 0.24 | 46.41 |
1216 | 3 | < 0.02 | < 0.02 | < 0.02 | -1.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1215 | 3 | < 0.02 | < 0.02 | < 0.02 | -1.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 3.1 | < 0.02 | < 0.02 | < 0.02 | -1.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 40.1 | 343.98 | 33.740 | 28.51 | 0.19 | 1.97 | 1.13 | 0.23 | 49.79 |
1209 | 74.7 | < 0.02 | < 0.02 | < 0.02 | -1.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1208 | 74.8 | 333.31 | 34.172 | 30.40 | -1.36 | 2.07 | 0.29 | 0.15 | 58.23 |
1210 | 74.9 | < 0.02 | < 0.02 | < 0.02 | -1.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1211 | 75 | < 0.02 | < 0.02 | < 0.02 | -1.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 199.7 | 322.05 | 34.292 | 31.65 | -1.84 | 2.15 | < 0.02 | < 0.02 | 63.23 |
1206 | 350.3 | 283.60 | 34.467 | 32.11 | -0.88 | 2.19 | < 0.02 | < 0.02 | 74.85 |
1204 | 440.2 | 234.60 | 34.638 | 32.48 | 0.37 | 2.22 | < 0.02 | < 0.02 | 94.07 |
1205 | 440.3 | < 0.02 | < 0.02 | < 0.02 | 0.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1203 | 700 | 224.06 | 34.665 | 33.03 | 0.35 | 2.27 | < 0.02 | < 0.02 | 113.86 |
1202 | 941.9 | < 0.02 | < 0.02 | < 0.02 | 0.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 941.9 | 228.93 | 34.669 | 33.20 | 0.12 | 2.27 | < 0.02 | < 0.02 | 118.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 2312 | Seabird | SBE-4 | 2312 | |
Fluorometer-CTD20-Chelsea-11-8206-01 | Chelsea | Aquatracker | 11-8206-01 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |