Deployment Details
Survey: - IN2017_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 2312,Fluorometer-CTD20-Chelsea-11-8206-01,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751
When: 2017-02-17 09:47 to 2017-02-17 11:28 UTC
Where: 65° 28.0' S 120° 47.1' E
Maximum Depth (m): 2559.1
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1209 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 0.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1210 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 0.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1208 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 0.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 4.8 | 345.36 | 33.810 | 28.35 | 0.80 | 1.92 | 0.93 | 0.28 | 46.76 |
1204 | 79.8 | < 0.02 | < 0.02 | < 0.02 | -1.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1203 | 79.9 | 327.32 | 34.247 | 31.17 | -1.79 | 2.11 | 0.04 | 0.12 | 62.48 |
1206 | 80 | < 0.02 | < 0.02 | < 0.02 | -1.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1205 | 80.3 | < 0.02 | < 0.02 | < 0.02 | -1.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 2558.9 | 251.49 | 34.639 | 32.99 | -0.31 | 2.26 | < 0.02 | < 0.02 | 109.42 |
1202 | 2559.1 | < 0.02 | < 0.02 | < 0.02 | -0.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 2312 | Seabird | SBE-4 | 2312 | |
Fluorometer-CTD20-Chelsea-11-8206-01 | Chelsea | Aquatracker | 11-8206-01 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |