Please login if you have access to particular applications.
Deployment Details
Survey: - IN2017_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 2312,Fluorometer-CTD20-Chelsea-11-8206-01,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 20 - SN 4718 ,Temperature CTD 22-SN 2751
When: 2017-02-11 12:19 to 2017-02-11 14:13 UTC
Where: 64° 40.9' S 118° 04.1' E
Maximum Depth (m): 3055.8
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1211 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 0.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1209 | 7.4 | 346.08 | 34.104 | 28.40 | 0.93 | 1.91 | 0.72 | 0.27 | 49.43 |
1210 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 0.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 7.9 | < 0.02 | < 0.02 | < 0.02 | 0.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1205 | 49.7 | 343.04 | 34.145 | 29.24 | 0.04 | 1.97 | 0.39 | 0.19 | 53.71 |
1206 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 0.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 50 | < 0.02 | < 0.02 | < 0.02 | -0.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1208 | 50.1 | < 0.02 | < 0.02 | < 0.02 | -0.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1204 | 124.5 | < 0.02 | < 0.02 | < 0.02 | -1.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1203 | 124.7 | 320.71 | 34.278 | 31.40 | -1.83 | 2.13 | < 0.02 | 0.04 | 64.92 |
1201 | 3055.8 | 245.64 | 34.648 | 32.83 | -0.23 | 2.25 | < 0.02 | 0.02 | 116.68 |
1202 | 3055.8 | < 0.02 | < 0.02 | < 0.02 | -0.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 2312 | Seabird | SBE-4 | 2312 | |
Fluorometer-CTD20-Chelsea-11-8206-01 | Chelsea | Aquatracker | 11-8206-01 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 20 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |