Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-11 10:47 to 2016-11-11 11:32 UTC
Where: 27° 20.8' S 153° 53.1' E
Maximum Depth (m): 447.1
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1212 | 5.3 | 213.52 | 35.631 | 0.04 | 24.82 | 0.09 | < 0.02 | 0.54 |
1211 | 20.6 | 213.79 | 35.630 | 0.03 | 24.78 | 0.09 | < 0.02 | 0.46 |
1210 | 40.3 | 221.03 | 35.679 | 0.03 | 23.43 | 0.10 | < 0.02 | 0.53 |
1209 | 60.4 | 217.95 | 35.697 | 0.03 | 23.15 | 0.11 | < 0.02 | 0.55 |
1208 | 81.4 | 208.25 | 35.742 | 1.00 | 22.15 | 0.19 | 0.05 | 0.63 |
1207 | 100.4 | 222.90 | 35.795 | 0.46 | 21.45 | 0.13 | 0.03 | 0.42 |
1206 | 139.9 | 210.22 | 35.754 | 2.20 | 20.29 | 0.24 | < 0.02 | 0.68 |
1205 | 200.7 | 214.51 | 35.735 | 2.30 | 19.67 | 0.25 | < 0.02 | 0.81 |
1204 | 250.2 | 192.80 | 35.596 | 5.52 | 18.43 | 0.45 | < 0.02 | 1.54 |
1203 | 351.1 | 179.89 | 35.336 | 9.92 | 15.98 | 0.75 | < 0.02 | 3.25 |
1202 | 400.6 | 196.46 | 34.882 | 17.13 | 11.14 | 1.19 | < 0.02 | 7.04 |
1201 | 447.1 | 197.49 | 34.799 | 18.55 | 10.45 | 1.28 | < 0.02 | 7.85 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |