Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-11 08:23 to 2016-11-11 09:45 UTC
Where: 27° 20.6' S 153° 58.2' E
Maximum Depth (m): 1296.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1224 | 5.3 | 214.33 | 35.649 | 0.02 | 24.71 | 0.10 | < 0.02 | 0.50 |
1223 | 20.7 | 214.37 | 35.643 | 0.03 | 24.67 | 0.10 | < 0.02 | 0.51 |
1222 | 40.7 | 215.22 | 35.649 | 0.03 | 24.49 | 0.10 | < 0.02 | 0.49 |
1221 | 60.3 | 214.64 | 35.701 | 0.08 | 22.96 | 0.13 | < 0.02 | 0.52 |
1220 | 80.6 | 212.05 | 35.743 | 0.48 | 22.36 | 0.15 | 0.09 | 0.57 |
1219 | 100.3 | 206.33 | 35.756 | 1.46 | 21.74 | 0.21 | 0.15 | 0.59 |
1218 | 150.7 | 211.16 | 35.769 | 1.67 | 20.71 | 0.22 | 0.07 | 0.66 |
1217 | 200.9 | 223.44 | 35.771 | 0.87 | 20.08 | 0.17 | 0.40 | 0.52 |
1216 | 250.7 | 189.90 | 35.628 | 5.19 | 18.95 | 0.44 | < 0.02 | 1.40 |
1215 | 301.4 | 185.12 | 35.484 | 7.43 | 17.34 | 0.59 | < 0.02 | 2.14 |
1214 | 350.9 | 191.33 | 35.379 | 8.95 | 15.81 | 0.67 | < 0.02 | 2.69 |
1213 | 400.5 | 193.74 | 35.223 | 11.43 | 14.15 | 0.83 | < 0.02 | 3.70 |
1212 | 451 | 192.31 | 34.988 | 15.28 | 12.18 | 1.07 | < 0.02 | 5.66 |
1211 | 500 | 200.57 | 34.904 | 16.72 | 11.25 | 1.15 | < 0.02 | 6.25 |
1210 | 601 | < 0.02 | < 0.02 | < 0.02 | 8.97 | < 0.02 | < 0.02 | < 0.02 |
1209 | 701.3 | 206.29 | 34.532 | 23.96 | 7.80 | 1.63 | < 0.02 | 13.89 |
1208 | 749.9 | 206.29 | 34.504 | 24.80 | 7.45 | 1.68 | < 0.02 | 15.58 |
1207 | 799 | 205.71 | 34.477 | 25.82 | 7.07 | 1.75 | < 0.02 | 18.09 |
1206 | 849 | 203.03 | 34.459 | 25.82 | 6.64 | 1.76 | < 0.02 | 18.02 |
1205 | 898.9 | 199.90 | 34.445 | 28.10 | 6.20 | 1.92 | < 0.02 | 26.41 |
1204 | 999.6 | 191.55 | 34.442 | 28.11 | 5.41 | 1.91 | < 0.02 | 26.48 |
1203 | 1100.7 | 182.71 | 34.460 | 31.85 | 4.77 | 2.18 | < 0.02 | 49.52 |
1202 | 1199.8 | 175.92 | 34.481 | 32.91 | 4.37 | 2.26 | < 0.02 | 58.78 |
1201 | 1296.5 | 168.19 | 34.505 | 33.95 | 3.93 | 2.35 | < 0.02 | 69.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |