Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-08 08:16 to 2016-11-08 08:32 UTC
Where: 27° 19.2' S 154° 09.4' E
Maximum Depth (m): 3300.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1224 | 7.8 | 214.02 | 35.631 | 0.02 | 24.62 | 0.11 | < 0.02 | 0.70 |
1223 | 20.6 | 214.06 | 35.631 | 0.02 | 24.60 | 0.11 | < 0.02 | 0.73 |
1222 | 44.3 | 214.91 | 35.638 | 0.02 | 24.48 | 0.10 | < 0.02 | 0.68 |
1221 | 74.7 | 206.29 | 35.704 | 0.64 | 22.59 | 0.19 | 0.02 | 0.86 |
1220 | 79.9 | 197.04 | 35.709 | 1.60 | 22.34 | 0.25 | 0.07 | 0.99 |
1219 | 99.8 | 217.14 | 35.763 | 0.44 | 21.84 | 0.16 | 0.06 | 0.74 |
1218 | 124.5 | 217.72 | 35.777 | 0.80 | 21.08 | 0.18 | 0.19 | 0.73 |
1217 | 239.4 | 189.27 | 35.667 | 4.62 | 19.64 | 0.41 | < 0.02 | 1.42 |
1216 | 350.6 | 191.24 | 35.476 | 7.42 | 17.25 | 0.58 | < 0.02 | 2.31 |
1215 | 549 | 198.16 | 34.901 | 16.82 | 11.18 | 1.16 | < 0.02 | 6.54 |
1214 | 599 | 201.60 | 34.765 | 19.27 | 10.01 | 1.32 | < 0.02 | 8.07 |
1213 | 700.6 | 206.20 | 34.568 | 23.06 | 8.23 | 1.57 | < 0.02 | 12.27 |
1212 | 799.3 | 205.40 | 34.472 | 26.05 | 7.03 | 1.77 | < 0.02 | 18.60 |
1211 | 902.1 | 199.99 | 34.438 | 28.48 | 6.06 | 1.94 | < 0.02 | 27.42 |
1210 | 1000 | 190.61 | 34.439 | 30.51 | 5.33 | 2.09 | < 0.02 | 38.29 |
1209 | 1200.9 | 174.85 | 34.485 | 33.29 | 4.24 | 2.30 | < 0.02 | 61.45 |
1208 | 1401.2 | 161.67 | 34.533 | 34.97 | 3.58 | 2.42 | < 0.02 | 79.99 |
1207 | 1600.6 | 154.48 | 34.581 | 35.88 | 3.06 | 2.50 | < 0.02 | 94.36 |
1206 | 1800.2 | 157.30 | 34.625 | 35.80 | 2.62 | 2.49 | < 0.02 | 101.26 |
1205 | 2001.1 | 166.90 | 34.660 | 35.00 | 2.34 | 2.43 | < 0.02 | 100.55 |
1204 | 2399.3 | 183.65 | 34.706 | 33.49 | 2.02 | 2.31 | < 0.02 | 98.28 |
1203 | 2600.6 | 190.48 | 34.723 | 33.05 | 1.79 | 2.27 | < 0.02 | 102.34 |
1202 | 2900.7 | 194.99 | 34.724 | 33.07 | 1.59 | 2.27 | < 0.02 | 107.55 |
1201 | 3300.2 | 199.28 | 34.720 | 33.27 | 1.34 | 2.29 | < 0.02 | 114.03 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |