Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-06 12:30 to 2016-11-06 12:40 UTC
Where: 27° 16.1' S 154° 16.3' E
Maximum Depth (m): 4176.8
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1224 | 6.6 | 218.26 | 35.665 | < 0.02 | 24.05 | 0.11 | < 0.02 | 0.72 |
1223 | 15.6 | 217.41 | 35.665 | < 0.02 | 24.05 | 0.10 | < 0.02 | 0.71 |
1222 | 43.5 | 219.64 | 35.668 | < 0.02 | 23.62 | 0.11 | < 0.02 | 0.73 |
1221 | 79.6 | 220.58 | 35.685 | < 0.02 | 23.19 | 0.12 | < 0.02 | 0.72 |
1220 | 120.2 | 205.75 | 35.755 | 1.62 | 21.70 | 0.22 | 0.13 | 0.82 |
1219 | 158.9 | 218.79 | 35.782 | 1.03 | 20.69 | 0.18 | 0.02 | 0.74 |
1218 | 199.6 | 219.24 | 35.787 | 1.34 | 20.48 | 0.20 | < 0.02 | 0.75 |
1217 | 248.5 | 217.05 | 35.773 | 1.61 | 20.36 | 0.21 | < 0.02 | 0.77 |
1216 | 299.7 | 185.30 | 35.636 | 5.35 | 19.23 | 0.46 | < 0.02 | 1.53 |
1215 | 349.9 | 193.65 | 35.553 | 6.17 | 17.79 | 0.51 | < 0.02 | 1.85 |
1214 | 439.1 | 194.99 | 35.289 | 10.41 | 14.70 | 0.77 | < 0.02 | 3.42 |
1213 | 487 | 199.37 | 35.138 | 12.71 | 13.22 | 0.92 | < 0.02 | 4.41 |
1212 | 599.4 | 201.64 | 34.804 | 23.14 | 10.48 | 1.58 | < 0.02 | 12.45 |
1211 | 703.9 | 205.89 | 34.566 | 23.15 | 8.20 | 1.58 | < 0.02 | 12.48 |
1210 | 898.6 | 201.15 | 34.439 | 28.34 | 6.09 | 1.93 | < 0.02 | 26.76 |
1209 | 1199.8 | 177.57 | 34.481 | 33.14 | 4.32 | 2.28 | < 0.02 | 59.69 |
1208 | 1498.6 | 158.64 | 34.554 | 35.43 | 3.37 | 2.47 | < 0.02 | 86.74 |
1207 | 1798.8 | 158.10 | 34.625 | 35.74 | 2.64 | 2.49 | < 0.02 | 100.22 |
1206 | 2100.1 | 171.32 | 34.676 | 34.51 | 2.24 | 2.39 | < 0.02 | 99.09 |
1205 | 2500.3 | 187.58 | 34.717 | 33.21 | 1.88 | 2.29 | < 0.02 | 100.31 |
1204 | 2899 | 199.23 | 34.723 | 33.12 | 1.51 | 2.28 | < 0.02 | 109.41 |
1203 | 3301.6 | 199.19 | 34.720 | 33.30 | 1.30 | 2.29 | < 0.02 | 115.04 |
1202 | 3699.3 | 200.08 | 34.717 | 33.43 | 1.23 | 2.30 | < 0.02 | 117.71 |
1201 | 4176.8 | 201.20 | 34.715 | 33.56 | 1.20 | 2.31 | < 0.02 | 119.67 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |