Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-04 09:59 to 2016-11-04 11:25 UTC
Where: 27° 19.4' S 154° 07.5' E
Maximum Depth (m): 3018.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1224 | 5.1 | 213.93 | 35.615 | 0.02 | 24.55 | 0.10 | < 0.02 | 0.62 |
1223 | 19.8 | 214.10 | 35.614 | < 0.02 | 24.53 | 0.10 | < 0.02 | 0.61 |
1222 | 45.8 | 216.78 | 35.740 | < 0.02 | 23.58 | 0.11 | < 0.02 | 0.59 |
1221 | 74.5 | 207.90 | 35.740 | 1.03 | 22.21 | 0.18 | 0.09 | 0.65 |
1220 | 80.1 | 204.95 | 35.752 | 1.32 | 22.07 | 0.19 | 0.16 | 0.77 |
1219 | 100.5 | 218.08 | 35.781 | 0.55 | 21.41 | 0.15 | 0.11 | 0.66 |
1218 | 125.7 | 221.92 | 35.788 | 0.44 | 21.05 | 0.14 | 0.30 | 0.63 |
1217 | 239.4 | 190.12 | 35.658 | 4.73 | 19.38 | 0.41 | 0.02 | 1.35 |
1216 | 351.1 | 190.30 | 35.437 | 7.90 | 16.58 | 0.61 | < 0.02 | 2.44 |
1215 | 550.4 | 201.20 | 34.778 | 18.97 | 10.10 | 1.28 | < 0.02 | 7.79 |
1214 | 600.8 | 203.48 | 34.656 | 21.15 | 9.11 | 1.43 | < 0.02 | 10.07 |
1213 | 700.9 | 206.51 | 34.535 | 23.86 | 7.83 | 1.62 | < 0.02 | 13.71 |
1212 | 800.4 | 204.64 | 34.458 | 26.69 | 6.69 | 1.81 | < 0.02 | 20.81 |
1211 | 900.6 | 197.71 | 34.437 | 29.05 | 5.83 | 1.97 | < 0.02 | 30.60 |
1210 | 1000.8 | 189.27 | 34.444 | 30.83 | 5.18 | 2.10 | < 0.02 | 41.27 |
1209 | 1200.7 | 173.95 | 34.488 | 33.28 | 4.22 | 2.28 | < 0.02 | 62.40 |
1208 | 1401.4 | 160.69 | 34.535 | 34.97 | 3.56 | 2.41 | < 0.02 | 81.28 |
1207 | 1601.9 | 153.32 | 34.586 | 35.91 | 3.01 | 2.48 | < 0.02 | 96.53 |
1206 | 1800.6 | 161.81 | 34.634 | 35.31 | 2.55 | 2.43 | < 0.02 | 98.07 |
1205 | 2001.4 | 168.68 | 34.663 | 34.79 | 2.33 | 2.39 | < 0.02 | 99.60 |
1204 | 2400.9 | 184.05 | 34.708 | 33.42 | 1.98 | 2.28 | < 0.02 | 99.67 |
1203 | 2601.3 | 190.17 | 34.720 | 33.09 | 1.83 | 2.26 | < 0.02 | 102.34 |
1202 | 2901 | 194.63 | 34.724 | 33.09 | 1.59 | 2.26 | < 0.02 | 109.03 |
1201 | 3018.5 | 195.75 | 34.723 | 33.14 | 1.58 | 2.26 | < 0.02 | 109.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |