Deployment Details
Survey: - IN2016_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 22,Conductivity CTD 20 - SN 3309,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 5450,Temperature CTD 22-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2016-11-02 00:35 to 2016-11-02 00:56 UTC
Where: 27° 16.9' S 154° 17.8' E
Maximum Depth (m): 4253.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1224 | 6.3 | 214.46 | 35.603 | 0.02 | 24.49 | 0.10 | < 0.02 | 0.31 |
1223 | 15.7 | 214.33 | 35.602 | 0.02 | 24.49 | 0.10 | < 0.02 | 0.27 |
1222 | 44.4 | 214.19 | 35.602 | 0.02 | 24.48 | 0.10 | < 0.02 | 0.28 |
1221 | 79.7 | 191.51 | 35.688 | 1.70 | 22.93 | 0.26 | 0.08 | 0.52 |
1220 | 120.3 | 221.70 | 35.767 | 0.03 | 21.78 | 0.13 | < 0.02 | < 0.02 |
1219 | 159.6 | 221.34 | 35.776 | 0.26 | 21.27 | 0.15 | 0.08 | 0.17 |
1218 | 200.3 | 193.47 | 35.710 | 3.57 | 20.35 | 0.34 | 0.02 | 0.78 |
1217 | 250.2 | 194.72 | 35.666 | 4.33 | 19.37 | 0.39 | < 0.02 | 1.05 |
1216 | 299.3 | 199.86 | 35.617 | 4.95 | 18.32 | 0.43 | < 0.02 | 1.26 |
415 | 351.1 | 188.96 | 35.453 | 7.73 | 16.71 | 0.60 | < 0.02 | 2.08 |
414 | 442.9 | 193.87 | 35.265 | 10.71 | 14.48 | 0.79 | < 0.02 | 3.28 |
413 | 500.1 | 198.12 | 35.128 | 12.85 | 13.05 | 0.92 | < 0.02 | 4.23 |
1212 | 599.6 | 200.57 | 34.770 | 19.00 | 10.15 | 1.32 | < 0.02 | 7.61 |
1211 | 699.4 | 204.77 | 34.559 | 23.43 | 8.18 | 1.61 | < 0.02 | 12.62 |
1210 | 898.3 | 198.43 | 34.440 | 28.58 | 6.11 | 1.96 | < 0.02 | 27.22 |
1209 | 1199.7 | 175.25 | 34.478 | 33.15 | 4.38 | 2.29 | < 0.02 | 57.95 |
1208 | 1499.5 | 155.82 | 34.554 | 35.62 | 3.38 | 2.49 | < 0.02 | 86.73 |
1207 | 1800.6 | 158.73 | 34.631 | 35.64 | 2.56 | 2.50 | < 0.02 | 99.39 |
1206 | 2102 | 174.36 | 34.680 | 34.15 | 2.25 | 2.38 | < 0.02 | 95.20 |
1205 | 2500.8 | 186.91 | 34.717 | 33.12 | 1.92 | 2.30 | < 0.02 | 99.41 |
1204 | 2900.8 | 195.08 | 34.723 | 33.04 | 1.52 | 2.30 | < 0.02 | 109.06 |
1203 | 3301.6 | 198.74 | 34.720 | 33.17 | 1.32 | 2.31 | < 0.02 | 114.60 |
1202 | 3699.7 | 200.17 | 34.718 | 33.25 | 1.23 | 2.32 | < 0.02 | 117.73 |
1201 | 4253.6 | 201.24 | 34.718 | 33.34 | 1.20 | 2.33 | < 0.02 | 119.99 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 20 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 5450 | Seabird | SBE3 plus | 5450 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |