Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 46
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-17 12:00 to 2016-09-17 12:26 UTC
Where: 32° 17.5' S 152° 52.5' E
Maximum Depth (m): 99.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 1218 | 5.5 | 224.91 | 35.684 | 0.26 | 21.34 | 0.14 | 0.09 | 0.03 | 0.29 |
| 1222 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1223 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1220 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1219 | 6 | < 0.02 | < 0.02 | < 0.02 | 21.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1221 | 6 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1224 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 21.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1217 | 20.7 | < 0.02 | < 0.02 | 0.31 | 20.96 | 0.15 | 0.12 | 0.03 | 0.32 |
| 1213 | 33.7 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1216 | 33.8 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1215 | 33.9 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1210 | 34 | 228.22 | 35.703 | 0.17 | 20.36 | 0.15 | 0.13 | 0.04 | 0.31 |
| 1212 | 34 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1211 | 34.1 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 34.4 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1209 | 53.7 | < 0.02 | < 0.02 | < 0.02 | 20.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1206 | 53.7 | < 0.02 | < 0.02 | < 0.02 | 20.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1204 | 53.8 | 217.86 | 35.667 | 1.59 | 20.11 | 0.24 | 0.24 | 0.18 | 0.69 |
| 1207 | 53.8 | < 0.02 | < 0.02 | < 0.02 | 20.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1205 | 54 | < 0.02 | < 0.02 | < 0.02 | 20.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1208 | 54.2 | < 0.02 | < 0.02 | < 0.02 | 20.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1203 | 84.8 | < 0.02 | < 0.02 | < 0.02 | 18.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1202 | 85.1 | < 0.02 | < 0.02 | 7.50 | 18.02 | 0.56 | < 0.02 | 0.30 | 2.36 |
| 1201 | 99.5 | 188.25 | 35.466 | 8.35 | 16.35 | 0.61 | < 0.02 | 0.13 | 2.55 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
| Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |