Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 43
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-16 23:13 to 2016-09-17 00:10 UTC
Where: 32° 28.5' S 154° 06.1' E
Maximum Depth (m): 1002.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1224 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1219 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1222 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1218 | 7 | 242.78 | 35.688 | 0.04 | 18.85 | 0.13 | 0.02 | < 0.02 | 0.74 |
1220 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1221 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1223 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1217 | 13.8 | < 0.02 | < 0.02 | 0.04 | 18.85 | 0.13 | 0.02 | 0.02 | 0.74 |
1216 | 34.2 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 34.4 | < 0.02 | < 0.02 | < 0.02 | 18.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1215 | 34.4 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 34.4 | 242.29 | 35.684 | 0.11 | 18.80 | 0.15 | 0.19 | 0.02 | 0.77 |
1213 | 34.6 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1209 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 16.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1208 | 100.1 | 230.99 | 35.613 | 3.62 | 16.92 | 0.35 | < 0.02 | 0.16 | 1.28 |
1211 | 100.2 | < 0.02 | < 0.02 | < 0.02 | 16.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1210 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 16.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 160.1 | < 0.02 | < 0.02 | 7.48 | 16.20 | 0.58 | < 0.02 | 0.02 | 2.30 |
1206 | 199.9 | < 0.02 | < 0.02 | 9.09 | 15.58 | 0.68 | < 0.02 | 0.02 | 2.84 |
1205 | 250.8 | < 0.02 | < 0.02 | 8.23 | 15.23 | 0.63 | < 0.02 | 0.02 | 2.64 |
1204 | 298.7 | < 0.02 | < 0.02 | 11.44 | 13.83 | 0.83 | < 0.02 | < 0.02 | 3.73 |
1203 | 499.4 | < 0.02 | < 0.02 | 18.58 | 10.20 | 1.28 | < 0.02 | < 0.02 | 7.37 |
1202 | 750.3 | < 0.02 | < 0.02 | 24.72 | 7.60 | 1.69 | < 0.02 | < 0.02 | 15.27 |
1201 | 1002.9 | 193.25 | 34.447 | 29.70 | 5.65 | 2.03 | < 0.02 | < 0.02 | 33.09 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WetLabs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |