Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 40
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-16 00:15 to 2016-09-16 01:15 UTC
Where: 33° 03.0' S 152° 52.5' E
Maximum Depth (m): 1001.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1221 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 21.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1224 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 21.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1219 | 6.7 | 218.35 | 35.724 | 0.48 | 21.82 | 0.15 | 0.05 | 0.05 | 0.58 |
1222 | 7 | < 0.02 | < 0.02 | < 0.02 | 21.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1223 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 21.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1220 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 21.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1218 | 18.4 | < 0.02 | < 0.02 | 0.51 | 21.82 | 0.15 | 0.05 | 0.05 | 0.56 |
1214 | 44.5 | 201.78 | 35.727 | 2.09 | 21.59 | 0.25 | 0.06 | 0.07 | 0.76 |
1216 | 44.5 | < 0.02 | < 0.02 | < 0.02 | 21.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1215 | 44.5 | < 0.02 | < 0.02 | < 0.02 | 21.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1217 | 44.7 | < 0.02 | < 0.02 | < 0.02 | 21.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 21.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1213 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 21.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1211 | 60.5 | < 0.02 | < 0.02 | < 0.02 | 21.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1210 | 60.5 | 177.04 | 35.702 | 4.81 | 21.09 | 0.41 | < 0.02 | 0.06 | 1.16 |
1209 | 100.9 | < 0.02 | < 0.02 | 1.40 | 20.45 | 0.18 | < 0.02 | 0.26 | 0.65 |
1208 | 130 | < 0.02 | < 0.02 | 3.61 | 19.93 | 0.32 | < 0.02 | 0.03 | 1.01 |
1207 | 258.7 | < 0.02 | < 0.02 | < 0.02 | 17.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1206 | 259.2 | < 0.02 | < 0.02 | 5.86 | 17.04 | 0.48 | < 0.02 | 0.10 | 1.75 |
1204 | 302.5 | < 0.02 | < 0.02 | 9.60 | 15.71 | 0.71 | < 0.02 | 0.02 | 2.99 |
1205 | 302.9 | < 0.02 | < 0.02 | < 0.02 | 15.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1203 | 499 | < 0.02 | < 0.02 | 16.68 | 11.01 | 1.15 | < 0.02 | < 0.02 | 6.22 |
1202 | 750.5 | < 0.02 | < 0.02 | 24.27 | 7.79 | 1.65 | < 0.02 | < 0.02 | 14.45 |
1201 | 1001.5 | 191.69 | 34.448 | 30.09 | 5.41 | 2.05 | < 0.02 | < 0.02 | 36.45 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |