Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 33
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-14 12:40 to 2016-09-14 13:36 UTC
Where: 31° 59.1' S 153° 17.8' E
Maximum Depth (m): 1002
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1224 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 21.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1220 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 21.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1221 | 7 | < 0.02 | < 0.02 | < 0.02 | 21.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1219 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 21.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1223 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 21.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1218 | 7.1 | 210.04 | 35.681 | 1.30 | 21.89 | 0.19 | < 0.02 | 0.05 | 0.73 |
1222 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 21.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1217 | 30 | < 0.02 | < 0.02 | 1.26 | 21.90 | 0.18 | < 0.02 | 0.06 | 0.74 |
1213 | 55.6 | < 0.02 | < 0.02 | < 0.02 | 21.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1216 | 55.7 | < 0.02 | < 0.02 | < 0.02 | 21.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 55.7 | < 0.02 | < 0.02 | < 0.02 | 21.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 55.8 | 204.86 | 35.725 | 1.66 | 21.70 | 0.21 | 0.03 | 0.06 | 0.88 |
1215 | 56 | < 0.02 | < 0.02 | < 0.02 | 21.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1211 | 80.4 | < 0.02 | < 0.02 | 0.43 | 21.22 | 0.14 | 0.11 | 0.11 | 0.72 |
1210 | 113.2 | < 0.02 | < 0.02 | 1.09 | 20.74 | 0.16 | < 0.02 | 0.24 | 0.76 |
1209 | 163 | < 0.02 | < 0.02 | < 0.02 | 19.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1206 | 163.1 | 175.16 | 35.633 | 6.11 | 19.63 | 0.49 | < 0.02 | 0.02 | 1.72 |
1207 | 163.1 | < 0.02 | < 0.02 | < 0.02 | 19.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1208 | 163.3 | < 0.02 | < 0.02 | < 0.02 | 19.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1205 | 233.2 | < 0.02 | < 0.02 | 8.91 | 16.51 | 0.66 | < 0.02 | 0.05 | 2.97 |
1204 | 299.5 | < 0.02 | < 0.02 | 13.55 | 13.19 | 0.95 | < 0.02 | < 0.02 | 4.94 |
1203 | 499.8 | < 0.02 | < 0.02 | 19.07 | 9.81 | 1.29 | < 0.02 | < 0.02 | 7.80 |
1202 | 751.8 | < 0.02 | < 0.02 | 26.15 | 6.94 | 1.77 | < 0.02 | < 0.02 | 19.53 |
1201 | 1002 | 190.57 | 34.447 | 30.19 | 5.32 | 2.06 | < 0.02 | < 0.02 | 38.11 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |