Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 30
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-13 20:17 to 2016-09-13 21:18 UTC
Where: 31° 30.5' S 153° 19.6' E
Maximum Depth (m): 1001.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 1220 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1221 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1217 | 4.8 | 220.98 | 35.678 | < 0.02 | 22.34 | 0.11 | < 0.02 | < 0.02 | 0.69 |
| 1223 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1224 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1218 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1222 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1219 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 22.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1216 | 29.7 | < 0.02 | < 0.02 | < 0.02 | 22.34 | 0.11 | < 0.02 | < 0.02 | 0.69 |
| 1211 | 59.7 | 220.27 | 35.788 | 0.43 | 21.21 | 0.14 | 0.05 | 0.16 | 0.75 |
| 1213 | 59.8 | < 0.02 | < 0.02 | < 0.02 | 21.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 59.9 | < 0.02 | < 0.02 | < 0.02 | 21.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1212 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 21.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1215 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 21.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1210 | 109.8 | < 0.02 | < 0.02 | 1.58 | 20.41 | 0.20 | < 0.02 | 0.09 | 0.81 |
| 1208 | 164.9 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1206 | 165.2 | 175.74 | 35.593 | 6.65 | 19.06 | 0.54 | < 0.02 | < 0.02 | 1.95 |
| 1209 | 165.2 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1207 | 165.2 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1205 | 209.8 | < 0.02 | < 0.02 | 7.16 | 17.36 | 0.55 | < 0.02 | < 0.02 | 2.15 |
| 1204 | 300.5 | < 0.02 | < 0.02 | 11.31 | 14.50 | 0.82 | < 0.02 | < 0.02 | 3.81 |
| 1203 | 500.1 | < 0.02 | < 0.02 | 18.83 | 10.26 | 1.30 | < 0.02 | < 0.02 | 7.94 |
| 1202 | 751 | < 0.02 | < 0.02 | 26.72 | 6.73 | 1.82 | < 0.02 | < 0.02 | 20.95 |
| 1201 | 1001.9 | 186.82 | 34.456 | 31.36 | 4.88 | 2.16 | < 0.02 | < 0.02 | 45.88 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
| Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |