Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 26
Gear: CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-12 22:28 to 2016-09-12 22:52 UTC
Where: 30° 33.9' S 153° 39.9' E
Maximum Depth (m): 30.2
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Nitrite (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|
| 1217 | 5.6 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1215 | 5.7 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1220 | 5.7 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1216 | 5.7 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1214 | 5.8 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1223 | 5.8 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1219 | 5.9 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1221 | 5.9 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1224 | 5.9 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1213 | 5.9 | 0.06 | 22.39 | 0.13 | < 0.02 | 0.02 | 0.41 | 
| 1218 | 5.9 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1222 | 6 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1209 | 29.6 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1203 | 29.7 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1205 | 29.7 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1210 | 29.7 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1207 | 29.8 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1201 | 29.8 | 0.35 | 22.39 | 0.14 | < 0.02 | 0.03 | 0.51 | 
| 1202 | 29.8 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1212 | 29.9 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1204 | 30.1 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1211 | 30.1 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1206 | 30.1 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1208 | 30.2 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
| Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) | 
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) | 
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) | 
| Transmissometer | SeaTech | Transmittance (%) |