Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-09 22:24 to 2016-09-09 22:50 UTC
Where: 36° 29.3' S 150° 17.2' E
Maximum Depth (m): 130.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 1220 | 5 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1218 | 5.2 | 236.97 | 35.707 | 1.34 | 18.60 | 0.21 | 0.25 | 0.14 | 0.92 |
| 1222 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1224 | 6 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1223 | 6 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1219 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1221 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 18.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1217 | 24.9 | < 0.02 | < 0.02 | < 0.02 | 18.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1211 | 44.1 | 240.68 | 35.657 | 0.88 | 18.24 | 0.19 | 0.13 | 0.11 | 0.73 |
| 1212 | 44.1 | < 0.02 | < 0.02 | < 0.02 | 18.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1216 | 44.2 | < 0.02 | < 0.02 | < 0.02 | 18.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 44.4 | < 0.02 | < 0.02 | < 0.02 | 18.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1213 | 44.4 | < 0.02 | < 0.02 | < 0.02 | 18.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1215 | 44.5 | < 0.02 | < 0.02 | < 0.02 | 18.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1209 | 64.7 | < 0.02 | < 0.02 | < 0.02 | 18.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1210 | 65.1 | < 0.02 | < 0.02 | < 0.02 | 18.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1207 | 85 | < 0.02 | < 0.02 | < 0.02 | 17.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1208 | 85.2 | < 0.02 | < 0.02 | < 0.02 | 17.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1205 | 115.7 | < 0.02 | < 0.02 | < 0.02 | 14.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1204 | 116 | < 0.02 | < 0.02 | < 0.02 | 15.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1203 | 116.1 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1206 | 116.1 | < 0.02 | < 0.02 | < 0.02 | 14.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1202 | 116.6 | 220.40 | 35.376 | 7.98 | 14.55 | 0.61 | < 0.02 | 0.20 | 2.84 |
| 1201 | 130.9 | 220.71 | 35.287 | 9.39 | 13.49 | 0.70 | < 0.02 | 0.13 | 3.40 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
| Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |