Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-06 18:30 to 2016-09-06 19:42 UTC
Where: 36° 15.0' S 153° 15.7' E
Maximum Depth (m): 1002.3
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1218 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1224 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1220 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1222 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1219 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1221 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1217 | 5.7 | 236.08 | 35.646 | 1.65 | 18.32 | 0.24 | 0.03 | 0.12 | 0.70 |
1223 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 18.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1216 | 31 | < 0.02 | < 0.02 | 2.28 | 18.07 | 0.28 | 0.06 | 0.15 | 0.79 |
1215 | 70.8 | < 0.02 | < 0.02 | 1.87 | 17.08 | 0.27 | 0.15 | 0.28 | 0.59 |
1212 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1209 | 100.5 | 241.57 | 35.592 | 2.05 | 16.77 | 0.28 | 0.18 | 0.33 | 0.66 |
1210 | 100.7 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1213 | 100.9 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1211 | 101.1 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 101.2 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1205 | 180.3 | 222.55 | 35.485 | 6.32 | 15.58 | 0.52 | < 0.02 | 0.08 | 1.81 |
1208 | 180.5 | < 0.02 | < 0.02 | < 0.02 | 15.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1206 | 180.6 | < 0.02 | < 0.02 | < 0.02 | 15.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 180.6 | < 0.02 | < 0.02 | < 0.02 | 15.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1204 | 249.8 | < 0.02 | < 0.02 | 11.09 | 13.65 | 0.81 | < 0.02 | 0.02 | 3.36 |
1203 | 499.7 | < 0.02 | < 0.02 | 19.52 | 9.55 | 1.34 | < 0.02 | < 0.02 | 7.42 |
1202 | 750.9 | < 0.02 | < 0.02 | 26.17 | 7.04 | 1.78 | < 0.02 | < 0.02 | 18.55 |
1201 | 1002.3 | 188.78 | 34.448 | 30.71 | 5.20 | 2.10 | < 0.02 | < 0.02 | 39.68 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |