Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-05 20:05 to 2016-09-05 20:28 UTC
Where: 36° 15.3' S 150° 17.4' E
Maximum Depth (m): 101
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1220 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1223 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1218 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1217 | 4.8 | < 0.02 | 35.725 | 3.04 | 17.79 | 0.37 | 0.53 | 0.17 | 1.18 |
1219 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1224 | 5 | < 0.02 | < 0.02 | < 0.02 | 17.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1221 | 5 | < 0.02 | < 0.02 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1222 | 5 | < 0.02 | < 0.02 | < 0.02 | 17.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1215 | 15.2 | < 0.02 | < 0.02 | < 0.02 | 17.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1212 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1211 | 15.5 | < 0.02 | < 0.02 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1216 | 15.6 | < 0.02 | < 0.02 | < 0.02 | 17.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1210 | 15.8 | 218.88 | 35.725 | 3.28 | 17.76 | 0.35 | 0.19 | 0.19 | 1.20 |
1213 | 15.8 | < 0.02 | < 0.02 | < 0.02 | 17.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 15.8 | < 0.02 | < 0.02 | < 0.02 | 17.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1203 | 35.2 | < 0.02 | 35.650 | 4.22 | 17.52 | 0.41 | 0.21 | 0.20 | 1.43 |
1208 | 35.4 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1206 | 35.4 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1207 | 35.4 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1204 | 35.5 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1205 | 35.7 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1209 | 35.7 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1202 | 60.8 | < 0.02 | 35.671 | 4.36 | 17.47 | 0.42 | 0.20 | 0.20 | 1.48 |
1201 | 101 | 210.76 | 35.658 | 5.12 | 17.00 | 0.46 | 0.11 | 0.20 | 1.75 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |