Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-05 18:59 to 2016-09-05 19:21 UTC
Where: 36° 15.2' S 150° 17.7' E
Maximum Depth (m): 15.3
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|
| 1222 | 7.9 | < 0.02 | 18.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 7.9 | < 0.02 | 17.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1224 | 8 | < 0.02 | 18.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1215 | 8 | < 0.02 | 18.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1216 | 8 | < 0.02 | 18.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1218 | 8 | < 0.02 | 18.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1219 | 8.1 | < 0.02 | 18.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1223 | 8.1 | < 0.02 | 18.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1221 | 8.1 | < 0.02 | 18.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1217 | 8.1 | < 0.02 | 18.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1220 | 8.2 | < 0.02 | 18.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1213 | 8.2 | 1.58 | 18.03 | 0.25 | 0.15 | 0.13 | 0.93 |
| 1206 | 14.7 | < 0.02 | 17.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1201 | 14.9 | 2.34 | 17.88 | 0.30 | 0.18 | 0.15 | 1.08 |
| 1210 | 15 | < 0.02 | 17.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1205 | 15 | < 0.02 | 17.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1208 | 15.1 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1202 | 15.1 | < 0.02 | 17.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1212 | 15.1 | < 0.02 | 17.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1209 | 15.1 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1211 | 15.2 | < 0.02 | 17.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1204 | 15.3 | < 0.02 | 17.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1203 | 15.3 | < 0.02 | 17.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1207 | 15.3 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
| Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |