Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-09-01 02:19 to 2016-09-01 03:13 UTC
Where: 34° 19.2' S 152° 03.8' E
Maximum Depth (m): 1000.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1000 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 18.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7577 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 18.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3922 | 5 | 248.85 | 35.675 | 0.09 | 18.07 | 0.13 | < 0.02 | 0.02 | 0.60 |
7431 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 18.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6787 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 18.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9339 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 18.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6554 | 23.4 | < 0.02 | < 0.02 | 0.16 | 17.54 | 0.14 | 0.02 | 0.04 | 0.54 |
2769 | 62.8 | < 0.02 | < 0.02 | < 0.02 | 16.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7060 | 62.8 | < 0.02 | < 0.02 | < 0.02 | 16.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
461 | 62.8 | < 0.02 | < 0.02 | < 0.02 | 16.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
318 | 62.9 | < 0.02 | < 0.02 | < 0.02 | 16.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
971 | 62.9 | 237.37 | 35.543 | 4.00 | 16.16 | 0.39 | 0.14 | 0.47 | 1.43 |
1711 | 62.9 | < 0.02 | < 0.02 | < 0.02 | 16.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3170 | 99 | < 0.02 | < 0.02 | < 0.02 | 14.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6948 | 99.1 | < 0.02 | < 0.02 | < 0.02 | 14.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4387 | 99.1 | 220.13 | 35.404 | 7.73 | 14.88 | 0.60 | < 0.02 | 0.11 | 2.46 |
344 | 99.1 | < 0.02 | < 0.02 | < 0.02 | 14.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8234 | 99.2 | < 0.02 | < 0.02 | < 0.02 | 14.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9502 | 99.2 | < 0.02 | < 0.02 | < 0.02 | 14.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3815 | 150 | < 0.02 | < 0.02 | 9.00 | 14.24 | 0.68 | < 0.02 | 0.03 | 2.91 |
7655 | 249.7 | 209.33 | 35.125 | 12.45 | 12.71 | 0.89 | < 0.02 | < 0.02 | 4.30 |
7951 | 499.6 | < 0.02 | < 0.02 | 21.63 | 8.84 | 1.47 | < 0.02 | < 0.02 | 10.09 |
1868 | 748.1 | < 0.02 | < 0.02 | 26.87 | 6.71 | 1.82 | < 0.02 | < 0.02 | 21.17 |
4897 | 1000.7 | 188.02 | 34.449 | 30.89 | 5.17 | 2.11 | < 0.02 | < 0.02 | 40.44 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |