Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-08-31 19:27 to 2016-08-31 20:39 UTC
Where: 34° 10.2' S 152° 34.0' E
Maximum Depth (m): 1000.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
6787 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 20.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9339 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 20.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7577 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 20.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1000 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 20.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3922 | 7.7 | 224.82 | 35.749 | 0.36 | 20.71 | 0.13 | 0.03 | 0.08 | 0.57 |
7431 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 20.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6554 | 24.4 | < 0.02 | < 0.02 | 0.38 | 20.72 | 0.13 | 0.02 | 0.08 | 0.57 |
971 | 54 | 224.96 | 35.749 | 0.39 | 20.72 | 0.13 | 0.02 | 0.08 | 0.57 |
461 | 54 | < 0.02 | < 0.02 | < 0.02 | 20.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2769 | 54.3 | < 0.02 | < 0.02 | < 0.02 | 20.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7060 | 54.7 | < 0.02 | < 0.02 | < 0.02 | 20.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
318 | 54.7 | < 0.02 | < 0.02 | < 0.02 | 20.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1711 | 54.7 | < 0.02 | < 0.02 | < 0.02 | 20.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
344 | 90.9 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4387 | 91.2 | 222.14 | 35.766 | 1.01 | 20.42 | 0.16 | < 0.02 | 0.25 | 0.55 |
8234 | 91.3 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6948 | 91.5 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9502 | 91.5 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3170 | 91.6 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3815 | 155.8 | < 0.02 | < 0.02 | 2.25 | 19.66 | 0.24 | < 0.02 | 0.22 | 0.73 |
7655 | 228.2 | < 0.02 | < 0.02 | 6.71 | 17.95 | 0.54 | < 0.02 | < 0.02 | 1.80 |
7951 | 498.9 | < 0.02 | < 0.02 | 17.55 | 10.92 | 1.21 | < 0.02 | < 0.02 | 6.75 |
1868 | 748.9 | < 0.02 | < 0.02 | 23.62 | 8.11 | 1.59 | < 0.02 | < 0.02 | 12.94 |
4897 | 1000.5 | 196.51 | 34.447 | 28.71 | 5.96 | 1.95 | < 0.02 | < 0.02 | 28.92 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |