Deployment Details
Survey: - IN2016_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22-SN 3908,Digiquartz with TC (Pressure),Fluorometer - WetStar Chl-a,Licor - LI-190SL Q46071,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22-SN 2751,Transmissometer
When: 2016-08-31 09:00 to 2016-08-31 09:58 UTC
Where: 34° 19.9' S 151° 45.6' E
Maximum Depth (m): 1001.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|
| 4853 | 1000.7 | < 0.02 | 34.452 | < 0.02 | 5.08 | < 0.02 | < 0.02 | < 0.02 |
| 7922 | 1001 | 187.08 | 34.453 | 30.88 | 5.08 | 2.11 | 0.03 | 42.08 |
| 2784 | 1001.2 | 186.91 | 34.452 | 30.91 | 5.07 | 2.11 | < 0.02 | 42.41 |
| 4217 | 1001.2 | 187.80 | 34.451 | 30.86 | 5.08 | 2.11 | 0.02 | 42.10 |
| 9705 | 1001.2 | < 0.02 | 34.452 | < 0.02 | 5.07 | < 0.02 | < 0.02 | < 0.02 |
| 1269 | 1001.2 | 186.95 | 34.452 | 30.98 | 5.06 | 2.12 | < 0.02 | 42.55 |
| 1418 | 1001.2 | < 0.02 | 34.452 | < 0.02 | 5.08 | < 0.02 | < 0.02 | < 0.02 |
| 6557 | 1001.3 | 187.04 | 34.451 | 30.88 | 5.07 | 2.11 | 0.02 | 42.07 |
| 8491 | 1001.3 | 186.91 | 34.451 | 30.86 | 5.09 | 2.11 | < 0.02 | 42.08 |
| 8002 | 1001.3 | 187.44 | 34.452 | 30.92 | 5.08 | 2.12 | 0.02 | 42.20 |
| 9575 | 1001.3 | 187.22 | 34.452 | 30.97 | 5.07 | 2.11 | < 0.02 | 42.31 |
| 9133 | 1001.4 | < 0.02 | 34.452 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 |
| 9057 | 1001.4 | < 0.02 | 34.452 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 |
| 1576 | 1001.4 | 186.77 | 34.451 | 30.98 | 5.06 | 2.12 | < 0.02 | 42.34 |
| 1000 | 1001.4 | < 0.02 | 34.452 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 |
| 975 | 1001.4 | < 0.02 | 34.451 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 |
| 8147 | 1001.5 | 186.24 | 34.452 | 30.99 | 5.06 | 2.12 | < 0.02 | 42.50 |
| 6323 | 1001.6 | 185.70 | 34.452 | 31.01 | 5.06 | 2.12 | < 0.02 | 42.49 |
| 5468 | 1001.6 | < 0.02 | 34.452 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 |
| 357 | 1001.8 | < 0.02 | 34.451 | < 0.02 | 5.07 | < 0.02 | < 0.02 | < 0.02 |
| 9571 | 1001.8 | 187.98 | 34.452 | 30.97 | 5.07 | 2.12 | < 0.02 | 42.31 |
| 9648 | 1001.9 | < 0.02 | 34.462 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 |
| 9157 | 1001.9 | < 0.02 | 34.452 | < 0.02 | 5.07 | < 0.02 | < 0.02 | < 0.02 |
| 9594 | 1001.9 | < 0.02 | 34.451 | < 0.02 | 5.07 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Digiquartz with TC (Pressure) | Digiquartz | 106117 | Pressure (decibars) | |
| Fluorometer - WetStar Chl-a | WET Labs | WETStar chl-a | WS3S-514P | Fluorescence (arbitrary units) |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |