Deployment Details
Survey: - IN2016_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 32
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20 - SN 3868,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3159,Pressure CTD 20,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 20 - SN 4722,Transmissometer - CTD 24 -CST-1421DR
When: 2016-02-06 02:12 to 2016-02-06 05:56 UTC
Where: 53° 02.0' S 72° 39.7' E
Maximum Depth (m): 132.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1208 | 93.9 | 323.84 | 33.920 | 24.53 | 2.77 | 1.89 | 0.28 | 14.00 |
1207 | 121.3 | 323.66 | 33.914 | 24.55 | 2.75 | 1.90 | 0.28 | 14.21 |
1205 | 123.3 | 323.21 | 33.912 | 24.64 | 2.73 | 1.92 | 0.28 | 14.51 |
1203 | 124 | 322.72 | 33.918 | 24.76 | 2.71 | 1.91 | 0.28 | 14.90 |
1215 | 124.2 | 316.33 | 33.936 | 25.62 | 2.42 | 1.99 | 0.26 | 19.75 |
1201 | 124.4 | 322.45 | 33.915 | 24.67 | 2.69 | 1.91 | 0.28 | 14.92 |
1204 | 124.4 | 322.85 | 33.915 | 24.71 | 2.72 | 1.91 | 0.28 | 14.76 |
1202 | 125 | 322.85 | 33.917 | 24.73 | 2.71 | 1.91 | 0.28 | 15.12 |
1209 | 125.1 | 322.36 | 33.917 | 24.82 | 2.70 | 1.91 | 0.28 | 15.33 |
1212 | 125.8 | 320.26 | 33.924 | 25.05 | 2.59 | 1.93 | 0.27 | 16.64 |
1213 | 126.5 | 319.91 | 33.926 | 25.12 | 2.54 | 1.95 | 0.27 | 17.30 |
1214 | 126.6 | 318.83 | 33.928 | 25.20 | 2.49 | 1.96 | 0.27 | 17.76 |
1211 | 126.8 | 321.16 | 33.922 | 25.05 | 2.60 | 1.93 | 0.27 | 16.26 |
1210 | 130.4 | 323.03 | 33.918 | 24.84 | 2.70 | 1.91 | 0.28 | 15.25 |
1206 | 132.2 | 322.85 | 33.914 | 24.63 | 2.73 | 1.90 | 0.28 | 14.56 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |