Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 110
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-16 01:40 to 2016-06-16 04:49 UTC
Where: 14° 16.8' S 169° 59.8' W
Maximum Depth (m): 3576.8
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 5 | 200.75 | 34.975 | < 0.02 | 28.62 | 0.18 | < 0.02 | 0.43 |
35 | 20.8 | 201.06 | 34.962 | < 0.02 | 28.29 | 0.18 | < 0.02 | 0.46 |
34 | 41.5 | 202.63 | 35.070 | < 0.02 | 27.94 | 0.18 | < 0.02 | 0.49 |
33 | 61.2 | 200.22 | 36.041 | < 0.02 | 27.81 | 0.22 | < 0.02 | 0.49 |
32 | 86.1 | 183.78 | 36.041 | 1.50 | 25.44 | 0.36 | 0.14 | 0.61 |
31 | 116.9 | 159.71 | 36.080 | 4.90 | 24.34 | 0.56 | 0.05 | 0.82 |
30 | 140.9 | 161.05 | 36.036 | 5.16 | 23.32 | 0.57 | 0.04 | 0.80 |
29 | 184.6 | 159.53 | 35.871 | 6.76 | 21.25 | 0.68 | < 0.02 | 1.15 |
28 | 234.5 | 154.57 | 35.509 | 9.34 | 18.59 | 0.87 | < 0.02 | 2.49 |
27 | 285.9 | 136.13 | 35.120 | 14.65 | 15.22 | 1.26 | < 0.02 | 5.95 |
26 | 337.1 | 124.16 | 34.852 | 19.73 | 12.91 | 1.60 | < 0.02 | 10.31 |
25 | 385.8 | 120.67 | 34.671 | 24.57 | 10.49 | 1.88 | < 0.02 | 15.56 |
24 | 420 | 129.29 | 34.595 | 26.72 | 9.33 | 1.98 | < 0.02 | 18.73 |
23 | 486.3 | 153.90 | 34.481 | 29.12 | 7.48 | 2.07 | < 0.02 | 23.22 |
22 | 565.3 | 153.41 | 34.468 | 31.56 | 6.33 | 2.22 | < 0.02 | 33.46 |
21 | 665.5 | 149.93 | 34.470 | 32.90 | 5.75 | 2.31 | < 0.02 | 40.59 |
20 | 766.1 | 143.05 | 34.480 | 34.43 | 5.23 | 2.42 | < 0.02 | 49.48 |
19 | 868.5 | 141.31 | 34.491 | 35.25 | 4.73 | 2.47 | < 0.02 | 58.20 |
18 | 968.1 | 142.16 | 34.500 | 35.69 | 4.36 | 2.51 | < 0.02 | 64.90 |
17 | 1067.3 | 141.13 | 34.519 | 36.30 | 3.91 | 2.55 | < 0.02 | 74.83 |
16 | 1166.5 | 141.31 | 34.538 | 36.56 | 3.53 | 2.57 | < 0.02 | 82.99 |
15 | 1267.1 | 139.34 | 34.556 | 36.95 | 3.29 | 2.60 | < 0.02 | 90.08 |
14 | 1366.8 | 138.36 | 34.567 | 37.11 | 3.13 | 2.61 | < 0.02 | 93.89 |
13 | 1467.3 | 141.31 | 34.581 | 36.89 | 2.91 | 2.60 | < 0.02 | 99.04 |
12 | 1566.7 | 144.61 | 34.594 | 36.76 | 2.70 | 2.58 | < 0.02 | 103.18 |
11 | 1667 | 146.80 | 34.606 | 36.66 | 2.52 | 2.58 | < 0.02 | 107.33 |
10 | 1765.8 | 148.36 | 34.612 | 36.55 | 2.45 | 2.57 | < 0.02 | 109.46 |
9 | 1936.3 | 149.70 | 34.625 | 36.56 | 2.29 | 2.56 | < 0.02 | 113.74 |
8 | 2137.6 | 151.76 | 34.644 | 36.54 | 2.06 | 2.56 | < 0.02 | 120.93 |
7 | 2336.3 | 152.83 | 34.653 | 36.44 | 1.95 | 2.55 | < 0.02 | 124.41 |
6 | 2535.1 | 154.04 | 34.659 | 36.36 | 1.89 | 2.55 | < 0.02 | 126.59 |
5 | 2735.5 | 156.13 | 34.666 | 36.25 | 1.78 | 2.54 | < 0.02 | 129.44 |
4 | 2935.8 | 163.64 | 34.673 | 36.11 | 1.71 | 2.52 | < 0.02 | 130.93 |
3 | 3199 | 162.07 | 34.678 | 35.85 | 1.65 | 2.51 | < 0.02 | 131.46 |
2 | 3401.9 | 164.80 | 34.680 | 35.72 | 1.62 | 2.50 | < 0.02 | 131.58 |
1 | 3576.8 | 165.74 | 34.682 | 35.70 | 1.62 | 2.49 | < 0.02 | 131.73 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |