Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 108
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-15 15:32 to 2016-06-15 18:56 UTC
Where: 15° 00.2' S 170° 00.0' W
Maximum Depth (m): 4892.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 4.6 | 201.38 | 35.000 | < 0.02 | 28.09 | 0.17 | < 0.02 | 0.66 |
35 | 23.7 | 200.71 | 34.998 | < 0.02 | 28.10 | 0.17 | < 0.02 | 0.67 |
34 | 50.7 | 199.32 | 35.359 | < 0.02 | 27.93 | 0.21 | < 0.02 | 0.64 |
33 | 75.1 | 173.02 | 36.020 | 2.14 | 26.35 | 0.43 | 0.36 | 0.87 |
32 | 99.9 | 162.21 | 36.136 | 4.12 | 24.88 | 0.52 | 0.22 | 0.96 |
31 | 152.3 | 160.60 | 36.037 | 5.70 | 22.41 | 0.59 | 0.02 | 0.95 |
30 | 203.1 | 161.14 | 35.742 | 7.29 | 20.03 | 0.72 | < 0.02 | 1.52 |
29 | 252 | 154.21 | 35.393 | 10.17 | 17.97 | 0.93 | < 0.02 | 3.05 |
28 | 301.9 | 144.08 | 35.054 | 14.30 | 15.28 | 1.22 | < 0.02 | 5.73 |
27 | 352.8 | 123.71 | 34.803 | 20.18 | 12.45 | 1.62 | < 0.02 | 10.53 |
26 | 402.8 | 125.32 | 34.673 | 23.61 | 10.65 | 1.81 | < 0.02 | 14.26 |
25 | 501.7 | 144.30 | 34.507 | 28.41 | 8.12 | 2.05 | < 0.02 | 21.17 |
24 | 601.3 | 159.80 | 34.445 | 30.99 | 6.28 | 2.17 | < 0.02 | 29.43 |
23 | 700.5 | 158.95 | 34.444 | 32.70 | 5.54 | 2.28 | < 0.02 | 39.24 |
22 | 803.4 | 151.00 | 34.468 | 34.39 | 4.90 | 2.41 | < 0.02 | 52.06 |
21 | 902.3 | 144.75 | 34.489 | 35.50 | 4.41 | 2.49 | < 0.02 | 61.98 |
20 | 1002.4 | 142.33 | 34.508 | 36.07 | 4.09 | 2.53 | < 0.02 | 70.27 |
19 | 1101.8 | 140.99 | 34.528 | 36.44 | 3.71 | 2.56 | < 0.02 | 78.93 |
18 | 1201.6 | 141.08 | 34.543 | 36.69 | 3.46 | 2.58 | < 0.02 | 84.83 |
17 | 1301.7 | 141.35 | 34.558 | 36.84 | 3.22 | 2.59 | < 0.02 | 90.57 |
16 | 1401.1 | 143.05 | 34.573 | 36.81 | 3.00 | 2.60 | < 0.02 | 95.64 |
15 | 1501.8 | 145.37 | 34.585 | 36.80 | 2.81 | 2.59 | < 0.02 | 100.16 |
14 | 1600.6 | 147.60 | 34.596 | 36.70 | 2.67 | 2.58 | < 0.02 | 103.31 |
13 | 1800.8 | 152.38 | 34.616 | 36.54 | 2.38 | 2.57 | < 0.02 | 110.76 |
12 | 2000.7 | 152.29 | 34.631 | 36.44 | 2.19 | 2.56 | < 0.02 | 115.84 |
11 | 2251.4 | 153.77 | 34.647 | 36.37 | 2.01 | 2.55 | < 0.02 | 121.33 |
10 | 2501.2 | 154.66 | 34.658 | 36.30 | 1.90 | 2.55 | < 0.02 | 125.68 |
9 | 2750.3 | 157.47 | 34.668 | 36.13 | 1.79 | 2.54 | < 0.02 | 128.86 |
8 | 3001 | 161.09 | 34.674 | 35.95 | 1.70 | 2.52 | < 0.02 | 129.98 |
7 | 3300.8 | 165.29 | 34.680 | 35.67 | 1.60 | 2.50 | < 0.02 | 131.63 |
6 | 3601.2 | 172.26 | 34.688 | 35.18 | 1.52 | 2.46 | < 0.02 | 130.13 |
5 | 3901.8 | 193.78 | 34.707 | 33.38 | 1.37 | 2.33 | < 0.02 | 119.33 |
4 | 4200.4 | 207.50 | 34.714 | 32.52 | 1.18 | 2.26 | < 0.02 | 116.80 |
3 | 4500.5 | 210.76 | 34.711 | 32.56 | 1.08 | 2.26 | < 0.02 | 119.49 |
2 | 4750.1 | 211.20 | 34.710 | 32.63 | 1.07 | 2.27 | < 0.02 | 120.59 |
1 | 4892.2 | 211.92 | 34.711 | 32.59 | 1.09 | 2.27 | < 0.02 | 120.49 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |