Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 107
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-15 08:54 to 2016-06-15 12:53 UTC
Where: 15° 29.8' S 170° 00.1' W
Maximum Depth (m): 5166.3
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 5 | 201.20 | 35.055 | < 0.02 | 27.83 | 0.18 | < 0.02 | 0.42 |
35 | 19.7 | 202.14 | 35.045 | < 0.02 | 27.83 | 0.17 | < 0.02 | 0.39 |
34 | 42.2 | 202.49 | 35.091 | < 0.02 | 27.78 | 0.17 | < 0.02 | 0.39 |
33 | 68.5 | 202.27 | 35.979 | < 0.02 | 26.80 | 0.22 | < 0.02 | 0.39 |
32 | 92.9 | 194.41 | 35.994 | 0.25 | 24.98 | 0.26 | 0.04 | 0.39 |
31 | 128.3 | 162.03 | 36.169 | 4.91 | 23.76 | 0.55 | 0.08 | 0.63 |
30 | 188.3 | 164.04 | 35.859 | 6.36 | 21.11 | 0.65 | < 0.02 | 0.92 |
29 | 238 | 162.79 | 35.532 | 8.24 | 18.61 | 0.80 | < 0.02 | 1.82 |
28 | 286.9 | 168.82 | 35.287 | 9.13 | 16.86 | 0.82 | < 0.02 | 2.48 |
27 | 336.8 | 146.22 | 34.844 | 16.99 | 13.34 | 1.38 | < 0.02 | 7.50 |
26 | 386.9 | 130.32 | 34.654 | 22.65 | 10.90 | 1.75 | < 0.02 | 12.77 |
25 | 465.9 | 143.09 | 34.509 | 27.59 | 8.45 | 2.01 | < 0.02 | 19.44 |
24 | 565.7 | 159.89 | 34.443 | 30.33 | 6.63 | 2.14 | < 0.02 | 27.04 |
23 | 665.1 | 160.38 | 34.437 | 32.46 | 5.53 | 2.27 | < 0.02 | 38.63 |
22 | 764.9 | 154.97 | 34.453 | 33.84 | 4.90 | 2.36 | < 0.02 | 48.50 |
21 | 866 | 148.94 | 34.479 | 34.85 | 4.44 | 2.44 | < 0.02 | 58.75 |
20 | 966.5 | 145.19 | 34.502 | 35.63 | 4.03 | 2.51 | < 0.02 | 69.12 |
19 | 1066.2 | 141.17 | 34.525 | 36.16 | 3.71 | 2.55 | < 0.02 | 77.27 |
18 | 1166 | 142.38 | 34.536 | 36.29 | 3.50 | 2.55 | < 0.02 | 81.98 |
17 | 1265.7 | 141.26 | 34.555 | 36.59 | 3.23 | 2.57 | < 0.02 | 88.99 |
16 | 1366.2 | 143.27 | 34.570 | 36.60 | 2.99 | 2.57 | < 0.02 | 94.50 |
15 | 1535.4 | 146.22 | 34.590 | 36.52 | 2.71 | 2.56 | < 0.02 | 101.28 |
14 | 1735.5 | 148.63 | 34.612 | 36.38 | 2.44 | 2.56 | < 0.02 | 108.79 |
13 | 1936.5 | 151.76 | 34.628 | 36.29 | 2.22 | 2.55 | < 0.02 | 114.65 |
12 | 2165.7 | 153.19 | 34.644 | 36.19 | 2.05 | 2.54 | < 0.02 | 119.83 |
11 | 2416 | 154.53 | 34.656 | 36.17 | 1.91 | 2.53 | < 0.02 | 124.45 |
10 | 2665.3 | 156.31 | 34.665 | 36.06 | 1.82 | 2.52 | < 0.02 | 127.73 |
9 | 2915.6 | 159.40 | 34.672 | 35.88 | 1.75 | 2.50 | < 0.02 | 128.85 |
8 | 3201.5 | 164.49 | 34.678 | 35.57 | 1.65 | 2.48 | < 0.02 | 129.73 |
7 | 3501.4 | 170.78 | 34.684 | 35.16 | 1.55 | 2.45 | < 0.02 | 129.54 |
6 | 3793.2 | 178.02 | 34.692 | 34.68 | 1.46 | 2.41 | < 0.02 | 128.20 |
5 | 4099.9 | 199.32 | 34.711 | 32.90 | 1.32 | 2.27 | < 0.02 | 117.19 |
4 | 4477.5 | 209.28 | 34.711 | 32.47 | 1.11 | 2.25 | < 0.02 | 119.02 |
3 | 4852.6 | 210.71 | 34.710 | 32.49 | 1.08 | 2.25 | < 0.02 | 120.27 |
2 | 5002.6 | 210.93 | 34.709 | 32.52 | 1.09 | 2.24 | < 0.02 | 120.58 |
1 | 5166.3 | 211.47 | 34.709 | 32.51 | 1.10 | 2.24 | < 0.02 | 120.74 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |